OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 57 of 193
H90202-7e-ID-B.docx
Extension:
b0:
extension flag disabled, Data from TR-Data2 will not be requested
b1:
extension flag enabled, Data from TR-Data2 will be requested
TR-DATA-2:
Selects the data types for read operation.
Bit
7
6
5
4
3
2
1
0
Function
Exten-
sion
-
-
ANT_
Ext
-
-
-
IN
IN:
(OperatingMode.BufferedReadMode.DataSelector.InputEvents)
(OperatingMode.NotificationMode.DataSelector.InputEvents)
(OperatingMode.ScanMode.DataSelector.InputEvents)
b0:
no Input states will be stored
b1:
Input states will be stored
ANT_Ext: Antenna Extended
(OperatingMode.BufferedReadMode.DataSelector.RSSI)
(OperatingMode.NotificationMode.DataSelector.RSSI)
b1:
Antenna number with RSSI
NOTE:
If Antenna Extended is enabled the checkbox for number of antenna must be disabled.
Antenna Extended is only available for Buffered Read Mode and Notification Mode.
Extension:
b0:
extension flag disabled, Data from TR-Data3 will not be requested
b1:
extension flag enabled, Data from TR-Data3 will be requested