PosiDRIVE Security Gate
ZMA-330, Ver. 6
Setting the DIP Switches •
43
DIP Switches 3 and 4: Backout Gate Reset Time
The following table lists the DIP switch positions to set the amount of time,
from 15 seconds to 60 seconds, that the gate stays up to let the patron enter the
facility. If DIP switch 7 is closed, enabling Backout Gate Arm Timeout, the gate
automatically closes if loop-B does not detect the vehicle within the configured
time.
Note:
This setting only affects the amount of time the patron has to pull onto
loop-B. Once the patron pulls onto loop B, the gate arm stays up until
the patron clears the loop.
If DIP switch 7 is open, disabling Backout Gate Arm Timeout, DIP switches 3
and 4 are not applicable; the gate arm stays up until the patron clears loop B.
DIP Switches 5 and 6: Gate Arm Length
The following table lists the DIP switch positions for the various gate arm
lengths.
Table 2-4 —
Backout Gate Reset Time DIP Switch Settings
Values
DIP Switch Positions
15 seconds
DIP switches 3 and 4 closed
30 seconds
DIP switch 3 open, DIP switch 4 closed
45 seconds
DIP switch 3 closed, DIP switch 4 open
60 seconds
DIP switches 3 and 4 open
Table 2-5 —
Gate Arm Length DIP Switch Settings
Values
DIP Switch Positions
10-12 feet (3.05m -
3.66m)
DIP switch 5 open, DIP switch 6 closed
14-16 feet (4.27m -
4.88m)
DIP switch 5 closed, DIP switch 6 open
18-20 feet (5.49m -
6.10m)
DIP switch 5 open, DIP switch 6 open
Содержание PosiDRIVE
Страница 1: ...PosiDRIVE Security Gate Installation Operation and Maintenance Manual ...
Страница 2: ......
Страница 26: ...18 Removing the Enclosure Cap ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 64: ...56 Aligning the Drive Mechanism ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 68: ...60 Accessing the Distributor Resource Center ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 90: ...82 Requesting a Repair ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 94: ...86 Index ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 95: ......