background image

PY600AC

Sliding Gate Opener

User Manual

Содержание PY600AC

Страница 1: ...PY600AC Sliding Gate Opener User Manual ...

Страница 2: ... the actual gate opener type The indicator light on the remote control unit will flicker when its button is pressed Main engine and gate can be unlocked with a disengagement wrench and the gate can be manually operated after disengagement Please make sure that nobody is around the main engine or gate when the switch is operated Please temporarily stop using the product if the main engine needs to ...

Страница 3: ...C D A B C D Remote control 2 4 Spring limit switch accessories box Magnetic limit switch accessories box 1 4 1 or Spring limit switch block Magnetic limit switch block 1 4 2 Limit switch block mounting screw M6X18 4 4 3 Foundation bolt M8 4 4 4 Nut M8 8 4 5 Flat washer Ø8 8 4 6 Spring washer Ø8 4 ...

Страница 4: ...ear rack 1m pc 3 Infrared sensor 1 4 0 8 5 6 9 7 4 1 2 3 Wireless keypad 1 5 Alarm lamp 1 6 Mounting plate 1 7 Protect cover for output gear 1 8 Hexagon head bolt M8 60 4 3 Technical parameters Model PY600AC Power supply 220V 50Hz 110V 60Hz Motor power 280W Gate moving speed 11 13m min ...

Страница 5: ... 20 C 70 C Package weight 9 4Kg 4 Installation PY600AC sliding gate opener is applicable to gate weight less than 600kg and length of the sliding gate less than 12m The drive mode adopts the rack and gear transmission This gate opener must be installed inside the enclosure or yard for protection 4 1 Installation drawing 0 8 5 6 9 7 4 1 2 3 Figure 1 Gate opener Wireless keypad optional Gate Infrare...

Страница 6: ...5 4 2 Size of main engine and accessories 4 2 1 Size of main engine 251 260 227 Figure 2 1 Spring Limit Switch 260 251 225 Figure 2 2 Magnetic Limit Switch 4 2 2 Size of mounting plate ...

Страница 7: ...e cables from damages please bury the motor power cable and controlling cable separately with two PVC tubes Concrete pedestal Please precast a concrete pedestal with the size can be 400mm x 250mm depth be 200mm in advance so as to firmly install SL600AC gate opener Please make sure the distance between the gate and gate opener is appropriate before casting the pedestal Embedded screws Concrete Pow...

Страница 8: ... the gear can be rotated easily Turn on 90 Figure 5 4 3 3 Gear rack installation Fix the mounting screws to the rack Put the rack on the output gear make the rack engage with the output gear then weld the mounting screw to the gate each screw with one solder joints firstly Manually move the gate gate should be moved smoothly after motor unlocked to check whether there is a fit clearance between ra...

Страница 9: ...rated flexibly when manually moved before installing the main engine Please note that for this product one control can only drive one main engine otherwise the control system will be damaged Earth leakage circuit breaker must be installed in where the gate movement can be seen and the minimum mounting height is 1 5m to avoid being touched by children After installation please check whether the mec...

Страница 10: ...ch switch stop stop block block Gear Gear rack rack Output Output gear gear Figure 8 The installation of spring limit switch stop block is shown in Figure 9 M6 18 M6 18 M6 18 M6 18 Figure 9 Magnetic limit switch The installation position of magnetic limit switch is shown in Figure 10 ...

Страница 11: ...llation of magnetic limit switch stop block is shown in Figure 11 M6 18 M6 18 M6 18 M6 18 Left side mounting Right side mounting Figure 11 Note The default setting is right side mounting According to actual situation please refer to the Note of section 4 3 5 1 and 4 3 5 2 Adjustment and operation to adjust 4 3 5 Control board wiring 4 3 5 1 Standard control board ...

Страница 12: ...20V 50HZ AC110V 60HZ L is Live wire N is Neutral wire and PE is grounding wire 2 Connect LAMP to D1 D2 voltage AC220V 50HZ AC110V 60HZ 3 Connect the motor wire U to the REV motor wire connect W to the FWD motor wire and connect V to the motor common wire 4 Connect C C to the capacitor wire X5 Terminal 24VDC Power supply for fittings 24VDC Electric current 50mA GND Power ground I R Photocell input ...

Страница 13: ...ion The distance between photocell receiver and photocell emitter should be more than 2 meters otherwise will affect the induction of the photocell If connect the infrared photocell please remove the short connection between I R and GND on the X5 terminal 24VDC 24VDC GND GND I R I R CLLM CLLM COM COM OPLM OPLM COM COM STP STP X5 X5 10A 10A 250V 250V CLS CLS OPN OPN X1 X1 PE PE N L X8 X8 X7 X7 V V ...

Страница 14: ...lash Press the button that to be learned on the remote control once The LED2 will be off Press the same button on the remote control twice the LED2 will flash several times and be off remote control learning complete A maximum of 25 remote controls can be learned Delete remote control To delete remote control that have been learned press and hold the learning button AN1 the indicator light LED2 wi...

Страница 15: ...ton button Close Close control control button button COM COM Figure 15 Wiring instruction 1 Connect L and N to the power supply of AC220V 50HZ AC110V 60HZ L is Live wire N is Neutral wire and PE is grounding wire 2 Connect LAMP to caution light voltage AC220V 50HZ AC110V 60HZ 3 Connect the motor wire MOT2 to the REV motor wire connect MOT1 to the FWD motor wire and connect MOTCOM to the motor comm...

Страница 16: ...e adjusted through potentiometer and dip switch so as to meet different installation requirements 13 13 12 12 SPEED SPEED GND GND VCC VCC OFF OFF ON ON X1 X1 HALL HALL U2 U2 S1 S1 VR3 VR3 VR4 VR4 LEARN LEARN POWER POWER J1 J1 13 13 VR1 VR1 VR2 VR2 SW1 SW1 1 2 3 4 5 Figure 16 Adjusting knob VR1 When meet obstacle reverse function is enabled DIP switch 5 on OFF position and the motor assembled with ...

Страница 17: ...3 OFF 4 OFF no automatic close function 5 Meet obstacle reversal function OFF enabled ON disabled Infrared connection Infrared photocell function In the closing process when infrared ray of the photocell is covered by people or objects during its detection range the gate will open immediately for security protection The distance between photocell receiver and photocell emitter should be more than ...

Страница 18: ... maximum of 40 remote controls can be learned Delete remote control To delete remote control that have been learned press and hold the learning button S1 the indicator light LEARN will be on Then release it until LEARN is off After the steps all the matched remote controls will be deleted The fourth button on the remote control is for pedestrian mode press the button while the door is closed it wi...

Страница 19: ...ocell is N C 2 Make sure that the photocell mounting position can be mutually aligned 3 Remove the obstacle 4 Reduce the sensitivity of obstacle 5 Change hall switch parts Remote control doesn t work 1 Battery level of the remote control is low 2 Remote control learning is not completed 1 Change the remote control battery 2 Re conduct remote control learning Press OPEN CLOSE button the gate is not...

Страница 20: ...Gate opens automatically Automatic close function has been turned on but with incorrect opening direction Please refer to the attentions under 4 3 5 1 and 4 3 5 2 to change the opening direction Warranty Warranty Ordinance 1 To repair against this warranty card and invoice during the warranty period 2 Warranty period 1 year after the date of invoice 3 Without unauthorized dismantling any product b...

Отзывы: