13
Adjustment and operation
Remote control operation
Three button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by three
buttons separately on the remote control.
Single button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by one
button circularly on the remote control.
Three
Three button
button mode
mode remote
remote control
control
Single
Single button
button mode
mode remote
remote control
control
A
B
C
D
OPEN
OPEN
A
B
C
D
CLOSE
CLOSE
STOP
STOP
CLOSE
CLOSE
OPEN
OPEN
STOP
STOP
Figure 14
Add extra remote control (remote control learning):
Remove the main engine housing, then take
out the upper cover of the control box, press the learning button AN1 on the control board, and
indicator light LED2 will flash. Press the button that to be learned on the remote control once, The
LED2 will be off. Press the same button on the remote control twice, the LED2 will flash several
times and be off; remote control learning complete. A maximum of 25 remote controls can be
learned.
Delete remote control:
To delete remote control that have been learned: press and hold the
learning button AN1, the indicator light LED2 will be on; Then release it until LED2 is off. After the
steps, all the matched remote controls will be deleted.
Note:
To disengage gate opener, move the gate to the middle position, then close the clutch and
press the open button of external button switch to open the gate.
If the gate opening direction is
wrong, you can change the direction through the toggle switch SW1 on the control board or
exchange the motor phase-sequence lines U and W. If the opening or closing limit is wrong,
please exchange limit switch lines CLLM and OPLM on the control board.
Содержание PY600AC