R•O•M M4000 Power - Series IV Shutter Door
Installation Instructions
6800 East 163
rd
Street • Belton, MO • 800-827-3692
Copyright © 2022. All Rights Reserved.
Page
1
of
17
FM-8.5-384 / D / 06-24-2022
Congratulations on your purchase of the R•O•M M4000 Power Operated Series IV Roll-up Shutter Door!
Please read and carefully follow these instructions!
You will need the following parts and tools for installing your Power Operator and Power Lock System;
please note that these are not included with your system.
•
Fasteners for drip rail and track (Self-tapping hex-head #10 machine or sheet metal screws are
recommended)
•
Drill
•
Drill bits-
#29, 11/64”, 3/16”, 3/8
, and 1/2
•
Single Pole Double Throw Momentary Switches for Door/Lock Input Switches (On)-Off-(On)
•
Door Ajar/Compartment White Light
•
10 Amp and 20 Amp Fuse and holder
•
Clear indoor/outdoor silicone sealant
•
Screwdriver
– Phillips
•
Wire cutters
•
Wire crimp
•
Tape measure
•
Marking pen
•
Pop rivet gun for 3/16” pop rivets
•
Rubber headed mallet
•
Paper towels
•
Rubbing alcohol
•
7/16” wrenches and / or sockets
•
DC current meter (suggested)
•
Wire nuts and/or solder less connector for joining 22 gauge wires to vehicle wiring
Note: Size vehicle wiring to allow 10 amps for each power operator system, if two are running