48
• Troubleshooting a Problem
ZMA-330, Ver.6
PosiDRIVE Security Gate
4.
Unbolt and remove the connecting rod.
5.
Turn the spherical bearing element within the bearing housing so that the bearing
surface is visible.
6.
Apply bearing grease to the bearing surface and move the bearing element around to
spread the grease evenly within the bearing housing.
7.
Replace the connecting rod and connecting rod bolts.
Troubleshooting a Problem
If the PosiDRIVE gate fails to operate properly, use the following table to troubleshoot
the problem. If you are still unable to correct the problem, contact your distributor. If
you are the distributor, contact Federal APD. See Appendix A,“Product Support”.
Table 3-8 —
Troubleshooting
Problem
Potential Cause
Solution
The gate is not operating.
The main power is off.
Turn the power on.
The wiring connections may
be loose.
Check all wiring
connections.
The breaker switch may be
tripped.
Reset the breaker switch.
Caution: if this is the
problem, the cause of the
current overload must be
identified and fixed.
The door safety switch is
out.
Make sure the access
door is on and secured.
Connecting Rod
Содержание PosiDRIVE
Страница 1: ...PosiDRIVE Security Gate Installation Operation and Maintenance Manual ...
Страница 2: ......
Страница 26: ...18 Removing the Enclosure Cap ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 64: ...56 Aligning the Drive Mechanism ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 68: ...60 Accessing the Distributor Resource Center ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 90: ...82 Requesting a Repair ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 94: ...86 Index ZMA 330 Ver 6 PosiDRIVE Security Gate ...
Страница 95: ......