Section 9 - System Programming

9–17

QUESTION 15
ZONE 5 TYPE & CS CODE

DEFAULT = 1035

Question 15, L1 & L2 - Zone 5 Type

Default = 10

Question 15, L3 & L4 - CS Code for Zone 5

Default = 35

Zone 5 = Instant (Perimeter) w/CS Reporting code = 35

QUESTION 16
ZONE 6 TYPE & CS CODE

DEFAULT = 1036

Question 16, L1 & L2 - Zone 6 Type

Default = 10

Question 16, L3 & L4 - CS Code for Zone 6

Default = 36

Zone 6 = Instant (Perimeter) w/CS Reporting code = 36

QUESTION 17
ZONE 7 TYPE & CS CODE

DEFAULT = 1037

Question 17, L1 & L2 - Zone 7 Type

Default = 10

Question 17, L3 & L4 - CS Code for Zone 7

Default = 37

Zone 7 = Instant (Perimeter) w/CS Reporting code = 37

QUESTION 18
ZONE 8 TYPE & CS CODE

DEFAULT = 1038

Question 18, L1 & L2 - Zone 8 Type

Default = 10

Question 18, L3 & L4 - CS Code for Zone 8

Default = 38

Zone 8 = Instant (Perimeter) w/CS Reporting code = 38

QUESTION 19
CS CODES for AMBUSH and AC LOSS

DEFAULT = AAAA

There are 4 locations (L1-L4) in this question as follows:

Question 19, L1 & L2 - Ambush Code

Default = AA

If an Ambush code is defined, User no. 6 is the Ambush code. The same rules apply here
regarding dialer format. If transmission is not desired, program AA in locations L1 & L2.
NOTE: AMBUSH transmissions are immediate and not abortable.

Question 19, L3 & L4 - AC Loss Code

Default = AA

The same rules apply here regarding dialer format. If transmission is not desired,
program AA in locations L3 & L4. NOTE: AC LOSS is reported 15 minutes after
detection.

QUESTION 20
CS CODES for PANIC and LOW BATTERY

DEFAULT = 22AA

There are 4 locations (L1-L4) in this question:

Question 20, L1 & L2 - Panic Code

Default = 22

The same rules for programming regarding dialer format apply here. If transmissions are
not desired, program AA in locations 1 & 2. NOTE: PANIC transmissions are immediate
and not abortable.

Question 20, L3 & L4 - Low Battery Code

Default = AA

The same rules for programming regarding dialer format apply here. If transmissions are
not desired, program AA in locations 3 & 4. LOW-BATTERY transmissions will be
reported 4 minutes after detection. LOW-BATTERY RESTORE CODE will be reported
within 4 minutes after detection of GOOD BATTERY condition.

Содержание XL-20

Страница 1: ...XL 20 Version 2 Hardwired Wireless System Hookup and Installation Instructions Subsidiary of Pittway Corp 149 Eileen Way Syosset NY 11791 N9825V1 04 98...

Страница 2: ...llations Use only hardwired smoke detectors in UL installations Wireless smoke detectors are not permitted in UL installations Wireless smoke detectors may be used with this control panel in non UL in...

Страница 3: ...heck all fuses Assure that the transformer and backup battery voltages are supplying the proper voltage levels Verify your programming information Read this manual thoroughly Note the proper model num...

Страница 4: ...6 2 Bypass 6 2 Quick Bypass 6 2 Auto Unbypass 6 2 Manual Unbypass 6 3 User Code Programming 6 3 User Deletion 6 3 Keypad Emergency Conditions 6 4 Section 7 Quick Command Modes 7 1 Quick Command Mode L...

Страница 5: ...er Modes 12 1 Appendix A Central Station Reporting Formats A 1 Standard 3X1 or 4X1 A 1 Extended 3X1 Ext or 4X1 Ext A 2 Partial Extended 3X1 Part Ext or 4X1 Part Ext A 2 3X2 or 4X2 A 3 ADEMCO 4X2 Expre...

Страница 6: ...this system for a UL Listed application These notes include information that you should be aware of before continuing with the installation and which if not observed could result in operational diffic...

Страница 7: ...itored and they should contact the CS Question 8 location 2 Open Close Transmission Users 4 12 Option to restrict open close transmission to users 4 and 12 keyfob 4 Tamper Disable Allows optional disa...

Страница 8: ...Upload download with remote commands with answering machine bypass Unattended and on line downloading Default Lockout option to prevent hostile account takeovers Quick Arming Quick Forced Arming and...

Страница 9: ...XL 20 Hookup and Installation Instructions 1 2...

Страница 10: ...SELF CONTAINED SIREN OR FIRE BURGLARY ALARM OUTPUT 11 5 13 1VDC 1A max _ AUX POWER 8 5 12VDC Reg 500mA Max SEE NOTE 2 SMOKE POWER 8 7 SEE DETAIL A SIREN SUPERVISION JP3 BELL OR SELF CONTAINED SIREN LE...

Страница 11: ...acle 5 Installation of equipment and wiring methods must be in accordance with the National Electrical Code and ANSI NFPA No 74 6 UL and CSFM require backup battery standby time of 24 hours minimum Un...

Страница 12: ...PANIC and BELL TEST On a FIRE condition a PULSED or TEMPORAL output can be generated There are separate bell cutoff times programmable for Burglary and Fire conditions within the programming sequence...

Страница 13: ...and smoke detectors ZONE INFORMATION HARDWIRED ZONES 9 10 Zone 1 Requires 2 2K EOL resistor Default DELAY 11 10 Zone 2 Requires 2 2K EOL resistor Default INTERIOR 12 13 Zone 3 Requires 2 2K EOL resist...

Страница 14: ...TTERY The RED and BLACK flying leads must be connected to a 12 VDC 4 7AH GELL CELL to serve as backup power in the event of AC loss A battery test occurs approximately every 4 5 minutes Low battery co...

Страница 15: ...r to the specifications for that particular device s current draw If the total current draw exceeds 500mA then use an additional power supply NFPA UL and the California State Fire Marshal require the...

Страница 16: ...s located within the middle of the PC board Secure the PC board to the middle mounting clip of the enclosure through the washer using the screw provided 5 Secure the remaining sides of the PC board to...

Страница 17: ...op of the control PC board as shown in the diagram above 2 Insert grounding lugs supplied into the left hand terminals of the antenna blocks and secure them to the cabinet with the screws provided 3 I...

Страница 18: ...re not provided for the type of surface 3 Complete the keypad wiring as required for the control with which the keypad is to be used 4 Replace the keypad cover assembly on the rear plate Starting at t...

Страница 19: ...XL 20 Hookup and Installation Instructions 4 2...

Страница 20: ...west priority indication Faulted burglary zones are displayed with the LED solidly ON while the system is disarmed NORMAL OFF 2 ARM DISARM LED This LED indicates whether the system is currently armed...

Страница 21: ...System not ready to be armed Slow Blink Indicates Installer programming mode Fast Blink Alarm Memory mode 7 STAY BUTTON The STAY button enables arming the system excluding zones programmed with the St...

Страница 22: ...try of certain commands the system will sound for approximately half a second PULSING A pulsing sound approximately half a second ON then OFF indicates a trouble condition such as AC Loss Low Battery...

Страница 23: ...XL 20 Hookup and Installation Instructions 5 4...

Страница 24: ...on 05 is set to 2 TO ARM Enter any programmed 4 digit user NOTE The factory default for User no 1 is 1234 The ARMED LED will light and the user may exit through an exit entry zone for the time period...

Страница 25: ...10 second period After this 10 second period the entire command including the user code must be entered After a successful bypass the keypad sounder will sound the acknowledge beep and the respective...

Страница 26: ...mode entry of the User number 6 code will ARM or DISARM the system and transmit the ambush code to the central station Furthermore if opening closing by User reporting is programmed User number 6 will...

Страница 27: ...at the same time Question 05 location 1 Question 04 location 4 FIRE Both Fire keys at the same time or 7 and 9 at the same time Question 05 location 1 Always AUDIBLE AUXILIARY Both Aux keys at the sam...

Страница 28: ...question 05 location 3 then Quick Force Arming will be permitted Quick Force Arming allows arming of the system without entry of a User code and bypasses any zones that are not ready It will report Us...

Страница 29: ...ine from the premises telephone line that the alarm system uses Connection is made with a person at the CS downloading computer and the account to be downloaded is verbally identified The CS computer...

Страница 30: ...defaulting the panel and entering keypad programming This prevents hostile account takeovers Installer Mode 1 System Default You can initiate a system default through the keypad by pressing the 1 and...

Страница 31: ...ion 03 from Keypad Programming if the panel is programmed for callback 4 Go to programming question 02 by entering the sequence 0 2 Enter the desired account number following each digit with This will...

Страница 32: ...ion is made the necessary remote communications sessions can take place Upload Download and Remote commands 4 Hang up the telephone or remove headset from the line to prevent interference that may aff...

Страница 33: ...XL 20 Hookup and Installation Instructions 8 4...

Страница 34: ...isted with each programming question Programming Questions Installer Programming This section of the manual defines the programming questions along with the values expected for each question DO NOT at...

Страница 35: ...ntrol panel to reach the callback location The callback number is the optional location of the EZ Mate Downloader where the control panel will call during a remote communications upload download etc s...

Страница 36: ...fault 1 Enter the digit for the desired message length from the table below in location L3 NOTE The checkmarks highlight which options are selected AC LINE FREQUENCY DIALING TYPE Digit 50 HZ 60 HZ SPL...

Страница 37: ...cation 1 SWINGER SHUTDOWN If selected 3 activations of the same zone within the same arming interval will not activate the bell or the dialer This applies only to Burglary zones and 24 Hr Audible zone...

Страница 38: ...or 7 9 at the same time will annunciate the keypad sounder PULSING SOUND and turn on the bell output PULSING SOUND It will transmit a CS code if programmed to do so in question 23 locations 1 and 2 K...

Страница 39: ...one momentary switches will start the entry delay time Question 05 L3 Quick Commands Quick Exit Default 0 Enter the digit from the table below in location L2 NOTE The checkmarks highlight which option...

Страница 40: ...ardless of the loop status RESTORE FOLLOWS LOOP Restores will be transmitted immediately upon zone restoral while the system is armed or upon system disarm regardless of the loop status USER ON LINE C...

Страница 41: ...S E 1 MINUTE 10 SECONDS F 3 MINUTES Question 06 L2 Exit Delay Default 6 Enter the desired exit time NOTE For UL applications the maximum exit delay shall not exceed 60 seconds Digit EXIT TIMEOUTS 0 1...

Страница 42: ...OUS SYSTEM OPTIONS DEFAULT 2C06 There are 4 locations L1 L4 within this question which defines various system timing options as follows Question 07 L1 Entry Delay 2 Default 2 Using the table in questi...

Страница 43: ...Test code to the central station at the interval selected in the absence of any other signal Select from daily 24 hour weekly 27 days 60 days or 90 days Transmission of any signal will reset the CS Te...

Страница 44: ...timing options as follows Question 08 L1 Bell Ring on Cancel Arm Bell Test Disarm Bell Test Bell Test Chirp Default 0 Digit BELL RING ON CANCEL ARM BELL TEST DISARM BELL TEST BELL TEST CHIRP 0 NONE 1...

Страница 45: ...ENABLE ARM STAY INSTANT ENABLE INSTANT KEY ARMS AWAY STAY KEY ARMS STAY 0 1 9 2 9 3 9 9 4 9 5 9 9 6 9 9 7 9 9 9 8 9 9 9 9 A 9 9 B 9 9 9 C 9 9 D 9 E F 9 ARM INSTANT ENABLE If selected this option allo...

Страница 46: ...ogramming Questions 11 18 represent all the options related to programmable zones 1 8 Each question contains 4 locations L1 L4 The first two locations L1 L2 define the zone type and options The second...

Страница 47: ...store code will be reported upon bell cutoff assuming the loop is restored unless Restore Follows Loop is selected in question 05 location 4 The Restore code will also be reported if the system is dis...

Страница 48: ...olation exists on the zone terminals 24 HR TROUBLE This zone type is always active independent of the system arming status Programming options include audible PULSING KEYPAD SOUNDER or silent Upon vio...

Страница 49: ...mber in locations L1 and L2 from the zone chart for the desired zone type Enter the desired Alarm code in locations L3 and L4 for this zone based on the dialer format selected QUESTION 11 ZONE 1 TYPE...

Страница 50: ...lt AA If an Ambush code is defined User no 6 is the Ambush code The same rules apply here regarding dialer format If transmission is not desired program AA in locations L1 L2 NOTE AMBUSH transmissions...

Страница 51: ...L2 Restore Code Default A L2 is the single digit system RESTORE CODE reported to the central station Restores will be reported for all Burglary or 24 hour zones by enabling this code digits 0 9 B F a...

Страница 52: ...FAULT AAAA There are 4 locations L1 L4 in this question Question 24 L1 RF Low Battery Code Default A Question 24 L2 RF Low Battery Restore Default A Question 24 L3 RF Supervisory Default A Question 24...

Страница 53: ...vent code Question 26 L4 Not Used QUESTION 27 NONSUPERVISED TAMPER RF ZONES DEFAULT 0000 There are 4 locations L1 L4 in this question Question 27 L1 L2 Nonsupervised RF Zones Default 00 Select the RF...

Страница 54: ...gits NON INVERT INVERT TRIGGER TYPE DEFINITION DESCRIPTION OF OPERATION 00 N A Smoke Power Trigger 1 Only Used in Fire Verification to reset smoke power 01 N A Smoke Power NO Verification Used to powe...

Страница 55: ...0000 If the control panel transmits a system test at a specific time of day enter the hour and minute in military time 24 hour clock as follows Question 29 L1 L2 Hour of Day 00 23 Default 00 Enter the...

Страница 56: ...2 Default 0 Question 32 L3 RF Remote Keyfob 2 Button 3 Default 0 Question 32 L4 RF Remote Keyfob 2 Button 4 Default 0 In locations L1 L4 enter the digit for the desired system options from the table...

Страница 57: ...T 0000 Question 36 L1 RF Remote Keyfob 6 Button 1 Default 0 Question 36 L2 RF Remote Keyfob 6 Button 2 Default 0 Question 36 L3 RF Remote Keyfob 6 Button 3 Default 0 Question 36 L4 RF Remote Keyfob 6...

Страница 58: ...valid digits from the tables below Question 08 RF Device 8 Serial Number Default 000000000 Select the options for RF Device 8 in L1 L9 Enter the valid digits from the tables below Question 09 RF Keyf...

Страница 59: ...g zone must be zone 5 To disable an RF point that has been previously programmed you must 1 Remove the RF enable for the appropriate zone in Question 26 and 2 Make the first 2 digits in the RF program...

Страница 60: ...s TO ENTER INSTALLER PROGRAMMING CODE INSTALLER 1 Where CODE Press the CODE button Press the asterisk button INSTALLER Enter the 4 DIGIT INSTALLER CODE default 2468 1 Press 1 button This indicates Ins...

Страница 61: ...e locations of the program sheet A 10 Inst RF Sprv ON B 11 Stay Inst RF Sprv ON C 12 TX LB RF Sprv ON D 13 Stay TX LB RF Sprv ON E 14 Inst TX LB RF Sprv ON F 15 Stay Inst TX LB RF Sprv ON How to Enter...

Страница 62: ...d PRESS THE STAY BUTTON TO EXIT THE SYSTEM PROGRAM MODE Question Acknowledgment The keypad will chirp on each keystroke In addition a beep will confirm advancement between question numbers Four beeps...

Страница 63: ...XL 20 Hookup and Installation Instructions 11 4...

Страница 64: ...r User code User Quick Arming 1 Quick Force Arming 2 Set Clock 3 Toggle Chime 6 On Line Downloading 9 Panic at the same time Fire 7 9 at the same time Auxiliary 1 3 at the same time Ambush Enter User...

Страница 65: ...XL 20 Hookup and Installation Instructions 12 2...

Страница 66: ...ceiver will release the phone line and process the data to its display and associated peripherals computer and printer If for any reason the digital communicator does not receive the Kissoff it will p...

Страница 67: ...thout parity 4 rounds of data There are 15 possible event codes each of which can have 15 different zone or user identifiers As a result a total of 225 individual events can be reported Examples 3X1 E...

Страница 68: ...nsmits in DTMF a total of 7 digits including the parity digit This format is similar to the Extended or 4X2 formats in that it can transmit a total of 225 individual reporting events However its advan...

Страница 69: ...nterior 5 133 24 Hour Alarm 6 134 Entry Exit 7 135 Day Night 8 136 Outdoor 9 137 Tamper A 140 General Alarm B 144 Sensor Tamper C 155 Foil Break D 156 Day Trouble FIRE ZONE TYPES Digit EVENT CODE ENGL...

Страница 70: ...sociated with them BYPASS TYPES Digit EVENT CODE ENGLISH OUTPUT AT CS RECEIVER 0 570 Zone Type Bypassed 1 571 Fire Zone Type Bypassed 2 572 24 Hour Zone Type Bypassed 3 573 Burg Zone Type Bypassed 4 5...

Страница 71: ...XL 20 Hookup and Installation Instructions A 6...

Страница 72: ...2 3 4 07 MISCELLANEOUS SYSTEM OPTIONS Default 2C06 1 2 3 4 08 BELL RING ON CANCEL ARM DISARM BELL TEST BELL TEST CHIRP Default 0000 1 2 3 4 09 ACCOUNT NUMBER 1 Default 1234 1 2 3 4 10 ACCOUNT NUMBER 2...

Страница 73: ...ult 0000 1 2 3 4 28 TRIGGERS 1 2 Default 0003 1 2 3 4 29 CS TEST TIME Default 0000 1 2 3 4 30 CID GROUP NUMBER Default AAAA 1 2 3 4 31 RF REMOTE KEYFOB 1 BUTTON DEFINITIONS Default 0000 1 2 3 4 32 RF...

Страница 74: ...BER 12 RF KEYFOB 4 DEFINITION Default 000000000 1 2 3 4 5 6 7 8 9 OPT TYPE SERIAL NUMBER 13 RF KEYFOB 5 DEFINITION Default 000000000 1 2 3 4 5 6 7 8 9 OPT TYPE SERIAL NUMBER 14 RF KEYFOB 6 DEFINITION...

Страница 75: ...XL 20 Hookup and Installation Instructions B 4...

Страница 76: ...e in time to prevent injury or death Passive Infrared Motion Detectors can detect intrusion only within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not...

Страница 77: ...XL 20 Hookup and Installation Instructions C 2...

Страница 78: ...he radio or television receiver are on different branch circuits If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may f...

Страница 79: ...XL 20 Hookup and Installation Instructions D 2...

Страница 80: ...F IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EV...

Страница 81: ...XL 20 Hookup and Installation Instructions E 2...

Страница 82: ...Notes...

Страница 83: ...1 9 Gl N9825V1 04 98 Copyright 1998 PITTWAY CORPORATION...

Отзывы: