XL-20 Hookup and Installation Instructions
9–12
INSTANT LED PULSE - Choosing this option causes the Instant LED to reflect the CS
monitoring status. When selected, by either the installer or a download, a pulsing Instant
LED indicates to the user that their account is not being monitored by the CS.
All dialer functions are maintained, regardless of whether this option is selected or not.
O/C USERS 4/12 - If this option is selected (along with other open and close codes
programmed), only keypad (User code 4) and keyfob 4 (User code 12) can report Open and
Close signals. No other keypad or keyfob will report to the CS.
TEMPORAL BELL - If this option is selected, the fire bell becomes temporal: 500ms
on/500ms off/500ms on/500ms off/1 second off. The temporal output option is available for
Fire conditions. If not selected, the fire bell output will be pulse.
Question 08, L3
Arm Instant, Arming Stay Instant,
Instant Key Arms Away, Stay Key Arms Stay
Default = 0
Digit
ARM INSTANT
ENABLE
ARM STAY/
INSTANT ENABLE
INSTANT KEY -
ARMS AWAY
STAY KEY -
ARMS STAY
0
1
9
2
9
3
9
9
4
9
5
9
9
6
9
9
7
9
9
9
8
9
9
9
9
A
9
9
B
9
9
9
C
9
9
D
9
E
F
9
ARM INSTANT ENABLE - If selected, this option allows the system to be armed in the
Instant mode. NOTE: If the INSTANT key is also enabled to arm away, only a keyfob can be
programmed to arm instant. This option must be selected to allow even the keyfob to arm in
this mode.
ARM STAY/INSTANT ENABLE - If selected, this option allows the system to be armed in
the Stay/Instant mode. NOTE: If the INSTANT or STAY keys are programmed to arm the
system, only a keyfob can be used to enable the system in this mode. This option must be
selected to allow even the keyfob to arm in this mode.
INSTANT KEY - ARMS AWAY - If this option is selected, pressing the INSTANT key on
the keypad will arm the system in the Away mode. NOTE: To use this option, Quick Arming
must be enabled in Question 5, location 3.
STAY KEY - ARMS STAY - If this option is selected, pressing the STAY key on the keypad
will arm the system in the Stay mode. NOTE: To use this option, Quick Arming must be
enabled in Question 5, location 3.
Question 08, L4
Not Used
Default = 0
Содержание XL-20
Страница 9: ...XL 20 Hookup and Installation Instructions 1 2...
Страница 19: ...XL 20 Hookup and Installation Instructions 4 2...
Страница 23: ...XL 20 Hookup and Installation Instructions 5 4...
Страница 33: ...XL 20 Hookup and Installation Instructions 8 4...
Страница 63: ...XL 20 Hookup and Installation Instructions 11 4...
Страница 65: ...XL 20 Hookup and Installation Instructions 12 2...
Страница 71: ...XL 20 Hookup and Installation Instructions A 6...
Страница 75: ...XL 20 Hookup and Installation Instructions B 4...
Страница 77: ...XL 20 Hookup and Installation Instructions C 2...
Страница 79: ...XL 20 Hookup and Installation Instructions D 2...
Страница 81: ...XL 20 Hookup and Installation Instructions E 2...
Страница 82: ...Notes...
Страница 83: ...1 9 Gl N9825V1 04 98 Copyright 1998 PITTWAY CORPORATION...