![FBII XL-20 Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/fbii/xl-20/xl-20_hookup-and-installation-instructions_3726746069.webp)
XL-20 Hookup and Installation Instructions
A–4
transmits at a much greater speed than the conventional pulse formats, since it uses DTMF
(touch-tones) instead of pulses to transmit the data, and it always sends a parity digit. Its
main advantage over all the other formats is its large number of Event codes (see tables
below) with the ability to pinpoint an event (Alarm, Trouble, Bypass, Restore, etc.) to a
specific sensor (up to 32 points in this system) and to report Openings/Closings for many
users (up to 15 users in this system).
For some Reporting codes, the first of the two programmable digits determines the PID
Event code to be transmitted. Other reporting codes transmit a dedicated PID Event code
regardless of the digit programmed in the first location. In both cases, if transmissions are
not desired, then program AA in locations 1 and 2. Refer to the following tables to select the
PID Event codes to be transmitted.
BURGLARY ZONE TYPES
Digit
EVENT
CODE
ENGLISH OUTPUT
AT CS RECEIVER
0
122
Silent Panic
1
123
Audible Panic
2
130
Burglary
3
131
Perimeter
4
132
Interior
5
133
24-Hour Alarm
6
134
Entry/Exit
7
135
Day/Night
8
136
Outdoor
9
137
Tamper
A
140
General Alarm
B
144
Sensor Tamper
C
155
Foil Break
D
156
Day Trouble
FIRE ZONE TYPES
Digit
EVENT
CODE
ENGLISH OUTPUT
AT CS RECEIVER
0
110
Fire Alarm
1
111
Smoke
2
112
Combustion
3
113
Water Flow
4
114
Heat
5
115
Pull Station
6
116
Duct
7
117
Flame
8
140
General Alarm
9
150
24-Hour Non-Burg
A
158
High Temperature
B
159
Low Temperature
C
200
Fire Supervisory
D
201
Low H2O Pressure
E
202
Low CO2
F
203
Gate Valve Sensor
24-Hour ALARM TYPES
Digit
EVENT
CODE,
ENGLISH OUTPUT
AT CS RECEIVER
0
100
Medical
1
101
Pendant Transmitter
2
120
Panic Alarm
3
122
Silent Panic
4
123
Audible Panic
5
130
Burglary
6
133
24-Hour Alarm
7
135
Day/Night
8
137
Tamper
9
140
General Alarm
A
150
24-Hour Non-Burg
B
151
Gas Detected
C
152
Refrigeration
D
153
Loss of Heat
E
154
Water Leakage
F
155
Foil Break
24-Hour TROUBLE TYPES
Digit
EVENT
CODE
ENGLISH OUTPUT
AT CS RECEIVER
0
100
Medical
1
122
Silent Panic
2
123
Audible Panic
3
137
Tamper
4
150
24-Hour Non-Burg
5
153
Loss of Heat
6
155
Foil Break
7
156
Day Trouble
8
158
High Temperature
9
159
Low Temperature
A
300
System Trouble
B
301
AC Loss
C
302
Low System Battery
D
310
Ground Fault
E
373
Fire Trouble
F
380
Sensor Trouble
Содержание XL-20
Страница 9: ...XL 20 Hookup and Installation Instructions 1 2...
Страница 19: ...XL 20 Hookup and Installation Instructions 4 2...
Страница 23: ...XL 20 Hookup and Installation Instructions 5 4...
Страница 33: ...XL 20 Hookup and Installation Instructions 8 4...
Страница 63: ...XL 20 Hookup and Installation Instructions 11 4...
Страница 65: ...XL 20 Hookup and Installation Instructions 12 2...
Страница 71: ...XL 20 Hookup and Installation Instructions A 6...
Страница 75: ...XL 20 Hookup and Installation Instructions B 4...
Страница 77: ...XL 20 Hookup and Installation Instructions C 2...
Страница 79: ...XL 20 Hookup and Installation Instructions D 2...
Страница 81: ...XL 20 Hookup and Installation Instructions E 2...
Страница 82: ...Notes...
Страница 83: ...1 9 Gl N9825V1 04 98 Copyright 1998 PITTWAY CORPORATION...