![FBII XL-20 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/fbii/xl-20/xl-20_hookup-and-installation-instructions_3726746038.webp)
Section 9 - System Programming
9–5
KEYPAD AUXILIARY
Digit
KEYPAD
PANIC
KEYPAD
FIRE
AUDIBLE
SILENT
0
NONE (K.P. CONDITIONS DISABLED)
1
9
2
9
3
9
9
4
9
5
9
9
6
9
9
7
9
9
9
C
9
D
9
9
E
9
9
F
9
9
9
NOTE: The Keypad Auxiliary Audible/Silent selection refers to keypad sounder only (not the
bell). Keypad Fire is always Audible. Keypad Panic may be Audible or Silent based on the
choice made in question 04, location 4.
KEYPAD PANIC - If AUDIBLE, pressing the two Panic keys at the same time (or [#]
& [*] at the same time) will annunciate the keypad sounder (STEADY SOUND) and turn on
the bell output (STEADY SOUND). If SILENT, it will not annunciate the keypad sounder
and turn on the bell output. In both cases, it will transmit a CS code if programmed to do so
in question 20, locations 1 and 2.
KEYPAD FIRE - If selected, pressing the two Fire keys at the same time (or 7 & 9 at
the same time) will annunciate the keypad sounder (PULSING SOUND) and turn on the bell
output (PULSING SOUND). It will transmit a CS code if programmed to do so in question
23, locations 1 and 2.
KEYPAD AUXILIARY - If AUDIBLE, pressing the two Aux keys at the same time (or
1 & 3 at the same time) will ONLY annunciate the keypad sounder (PULSING SOUND). If
SILENT, then it will not annunciate the keypad sounder or turn on the bell output. It will
transmit a CS code if programmed to do so in question 23, locations 3 and 4.
Question 05, L2
Misc Options
Default = 0
Enter the digit from the table below in location L2. NOTE: The checkmarks highlight which
options are selected.
DIALING PULSE TYPE
Digit
ARM
FAULTED
US
EUROPEAN
AUTO
STAY
POOL ZONE
(ZONE 4)
0
9
1
9
9
2
9
3
9
9
4
9
9
5
9
9
9
6
9
9
7
9
9
9
8
9
9
9
9
9
9
A
9
9
B
9
9
9
C
9
9
9
D
9
9
9
9
E
9
9
9
F
9
9
9
9
ARM FAULTED - If enabled, this allows the user to arm the system independent of the
status of any delay or interior zones. If the system is armed with any delay or interior zone
Содержание XL-20
Страница 9: ...XL 20 Hookup and Installation Instructions 1 2...
Страница 19: ...XL 20 Hookup and Installation Instructions 4 2...
Страница 23: ...XL 20 Hookup and Installation Instructions 5 4...
Страница 33: ...XL 20 Hookup and Installation Instructions 8 4...
Страница 63: ...XL 20 Hookup and Installation Instructions 11 4...
Страница 65: ...XL 20 Hookup and Installation Instructions 12 2...
Страница 71: ...XL 20 Hookup and Installation Instructions A 6...
Страница 75: ...XL 20 Hookup and Installation Instructions B 4...
Страница 77: ...XL 20 Hookup and Installation Instructions C 2...
Страница 79: ...XL 20 Hookup and Installation Instructions D 2...
Страница 81: ...XL 20 Hookup and Installation Instructions E 2...
Страница 82: ...Notes...
Страница 83: ...1 9 Gl N9825V1 04 98 Copyright 1998 PITTWAY CORPORATION...