4. INSTANT LED
This LED displays whether the system has been armed in the STAY/INSTANT mode,
INSTANT mode, or indicates if the account is not being monitored by the CS.
STAY/INSTANT means that the system is currently armed, all delay zones are instant
and all interior zones are bypassed. INSTANT means that the system is currently armed,
all delay zones are instant and no zones are bypassed. NOTE: See programming question
05, location 2 and question 08, location 2.
ON
Delay zones are currently instant
OFF
Delay zones are normal
PULSE
Account is not being monitored by the CS
5. AC/LOW BATTERY LED
This indicator light displays the current power status of the panel as follows:
ON
AC is present
OFF
No AC, running on battery backup
Slow Blink
Low-battery condition detected
6. READY LED
This LED displays whether the system is ready for arming. The READY light is common
to all BURGLARY ZONES with the following indications:
ON
System ready to be armed
OFF
System not ready to be armed
Slow Blink
Indicates Installer programming mode
Fast Blink
Alarm Memory mode
7. STAY BUTTON
The STAY button enables arming the system, excluding zones programmed with the Stay
Option. This will provide exterior protection of the location while allowing full access
throughout the interior.
8. BYPASS BUTTON
The BYPASS button is used to temporarily exclude protection of a specific zone.
9. INSTANT BUTTON
The INSTANT button enables arming the system, eliminating the entry delays. If
enabled with the STAY button, it enables arming the system in the STAY/INSTANT
mode.
The INSTANT modes are enabled in question 05, location 2.
10. CODE BUTTON
The CODE button is used to enter the Installer Programming mode and for entry of user
codes.
11. KEYPAD AUXILIARY KEYS
Pressing the two keys (top and bottom) labeled “P” at the same time initiates a CS
transmission, if programmed, of PANIC, AUXILIARY, or FIRE, annunciates the keypad
sounder and turns on the bell output. If not programmed to transmit, these keys can only
result in a local warning as follows (see question 05, location 1):
Keypad Sounder - Steady for PANIC, pulsing for FIRE and AUXILIARY
Bell Output - Steady for PANIC, pulsing for FIRE
Содержание XL-20
Страница 9: ...XL 20 Hookup and Installation Instructions 1 2...
Страница 19: ...XL 20 Hookup and Installation Instructions 4 2...
Страница 23: ...XL 20 Hookup and Installation Instructions 5 4...
Страница 33: ...XL 20 Hookup and Installation Instructions 8 4...
Страница 63: ...XL 20 Hookup and Installation Instructions 11 4...
Страница 65: ...XL 20 Hookup and Installation Instructions 12 2...
Страница 71: ...XL 20 Hookup and Installation Instructions A 6...
Страница 75: ...XL 20 Hookup and Installation Instructions B 4...
Страница 77: ...XL 20 Hookup and Installation Instructions C 2...
Страница 79: ...XL 20 Hookup and Installation Instructions D 2...
Страница 81: ...XL 20 Hookup and Installation Instructions E 2...
Страница 82: ...Notes...
Страница 83: ...1 9 Gl N9825V1 04 98 Copyright 1998 PITTWAY CORPORATION...