XL-1S to XL-2 Comparison
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
The XL-1S is an enhanced version of the XL-2 control panel. Some new features have been added and others
have been modified. The following is a quick comparison.
XL-1S NEW & MODIFIED FEATURES
XL-2 SIMILAR FEATURES
Call Waiting /PBX Dialing - 1 digit entry
(program quest. #01 & #02)
Multiple digits required
Smoke Power or Programmable
Trigger #1 Output/Terminal P1-T1
(program quest. #07)
Smoke Power Only
Programmable Trigger #2
Output/Terminal P1-T2 (program quest.
#07)
NONE
CS Test Timer Offset (program quest.
#14)
NONE
Cancel Code (program quest. #18)
NONE; Restore Code Only
European Ring Detect (program quest.
#05)
NONE
Exit Error Warning (always enabled)
NONE
Bypass In Stay - Any Controlled Zone can
be Bypassed in Stay Mode (program quests.
#10-13)
Interior Zones Only Bypassed in Stay Mode
System Stabilization on Power Up - to
Eliminate Motion Detector False Alarms
NONE
Fast Loop Response (10 msec) Option
by Zone (program quests. #10-13)
NONE
AC (50/60 HZ) Based System Real Time
Clock (program quest. #05)
Software Based System Timing
Bell Supervision - New NFPA 72
Requirement (program quest. #13)
NONE
Stay Mode 40 Sec. Dialer Delay w/Bell
& Keypad Sounder Warning for All
Zones (program quest. #05)
Stay Mode Entry Delay w/Keypad Sounder
Warning for Exit/Entry Zones Only
LED Zone Display & Keypad Sounder
during Entry (always enabled)
Keypad Sounder Only
XL-1S FEATURE CHANGES
XL-2 SIMILAR FEATURES
5 Zones - 4 Programmable & Wired
Panic or Keyswitch Zone (program
quest. #10-13)
7 Zones - 6 Programmable & Wired
Panic or Keyswitch Zone
System Wide Restore Code Enable
(program quest. #19)
Restore Codes selectable by each zone
System Wide 15 Sec. Dialer Delay for
controlled zones (program quest. #07)
15 Sec. Dialer Delay selectable by each zone
User 5 - Arm Only User capability
removed
User 5 - Arm Only User optional
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...