Section 8 - System Programming
8–13
4x2: Enter the desired first digit of the alarm code in location L3 and the second digit in L4
for the specific zone. Both digits will be used for all transmissions.
For more information on CS Reporting Formats refer to Appendix A at the back of this manual.
QUESTIONS 10 - 13 ZONES 1 - 4
There are 4 locations (L1-L4) within each of these questions which define the operation of the
zones. Enter a 2-digit number in locations L1 and L2 from the zone chart for the desired type
for this zone. Enter the desired alarm code in locations L3 and L4 for this zone relative to the
dialer format selected.
QUESTION 10
ZONE 1 TYPE & CS CODE
DEFAULT = 2031
Question 10, L1 & L2 - Zone 1 Type
Default = 20
Question 10, L3 & L4 - CS Code for Zone 1
Default = 31
Zone 1 = Delay (Entry/Exit) w/CS reporting code = 31
QUESTION 11
ZONE 2 TYPE & CS CODE
DEFAULT = 4132
Question 11, L1 & L2 - Zone 2 Type
Default = 41
Question 11, L3 & L4 - CS Code for Zone 2
Default = 32
Zone 2 = Interior Follower w/CS reporting code = 32
QUESTION 12
ZONE 3 TYPE & CS CODE
DEFAULT = 1033
Question 12, L1 & L2 - Zone 3 Type
Default = 10
Question 12, L3 & L4 - CS Code for Zone 3
Default = 33
Zone 3 = Instant (Perimeter) w/CS reporting code = 33
QUESTION 13
ZONE 4 TYPE & CS CODE
DEFAULT = 1034
Question 13, L1 & L2 - Zone 4 Type
Default = 10
Question 13, L3 & L4 - CS Code for Zone 4
Default = 34
Zone 4 = Instant (Perimeter) w/CS reporting code = 34
If zones 3 & 4 are programmed as DELAY zones, they follow ENTRY DELAY #2. If zone 4 is
programmed as a FIRE zone, Bell Supervision is enabled. See Bell Output Terminal connections
for description.
QUESTION 14
CS TEST OFFSET
DEFAULT = 083B
There are 4 locations L1-L4 in this question.
Question 14, L1 & L2 - CS Test Offset Hours
Default = 08
Question 14, L3 & L4 - CS Test Offset Minutes
Default = 3B
This option allows the installer to initiate the automatic CS Test sequence some time in
advance from the time the installation is completed within the same day. For example, if the
installation is completed at 6:00 PM and the test is desired at 1:00 PM, then program an
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...