![FBII XL-1S Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/fbii/xl-1s/xl-1s_hookup-and-installation-instructions_547073013.webp)
Section 2 - System Wiring and Hookup
2–3
9 (-) & 12 (+)
REGULATED POWER (11.5 - 13.1VDC):
The total regulated output power for motion detectors and other external
devices is 500mA at 11.8 - 12.5V for residential applications, or 12.0 -
12.5V for commercial applications, with less than 100 mVPP ripple. The
total regulated output capacity of the XL-1S includes the power available
from these terminals (9 & 12) as well as the power used by the keypads
and smoke detectors. Therefore, to determine the total power available
from these terminals subtract the power consumed by the keypads and
smoke detectors. See Auxiliary Device Current Draw Worksheet.
12 (+) 13 (-)
SMOKE DETECTOR POWER OR TRIGGER #1 OUTPUT:
SMOKE DETECTOR POWER:
This system will accept 9.5 - 12VDC four (4)
wire smoke detectors only. Approximately 50mA of current is available at
these terminals for powering all detectors and an EOL relay model
ESL2048. For UL installations see wiring diagram for hookup. NOTE:
Trigger #1 must be selected for smoke detector power (see program
question #07, location 3).
These terminals adhere to the fire verification and reset logic, which is
explained in the zone types section of this manual. Manual reset of smoke
detector power can be accomplished by entering a valid user code after
clearing alarm memory or using the asterisk (*) key.
14 15 16 17
TELEPHONE LINE:
Connect the model 368 cord as follows; 14 (GREEN = Telco Tip), 15 (RED
= Telco Ring), 16 (BROWN = Home Tip), 17 (GRAY = Home Ring). Insert
the plug into an USOCRJ31X jack (or a CA31A jack for Canadian
installations).
The FCC registration number is (AE398E-69554 AL-E), and the ringer
equivalence is (0.0B). The system should not be connected to party lines,
or coin operated phones.
If this control panel will be used for uploading, downloading or remote command applications, the
telephone line connected to the control panel
must not
be shared with a fax machine or modem.
Furthermore, this device should not be connected to a phone line that has call waiting, unless the
call waiting interrupt numbers are programmed into the panel dialing sequence.
18(+)
CONSTANT DC POWER:
This terminal delivers constant unregulated 10.0-15.5VDC power for
devices requiring a constant power such as VS279. It is connected to a
bell fuse (F3). NOTE: Constant power for these devices can also be
obtained by splicing the RED (+) battery lead with an in-line fuse of 3
Amps.
19(+) & 20(-)
BELL OUTPUT:
The total output power available for sounding devices is 1 amp at 10.5 -
15.5 VDC for residential applications, or 12.0 - 14.4 VDC for commercial
installations (750 mA for UL installations). These terminals will deliver
CONSTANT output on BURGLARY, AUDIBLE PANIC and BELL TEST.
On a FIRE condition, a PULSED output will be generated. There are
separate bell cutoff times programmable for Burglary and Fire conditions
within the programming sequence. For UL Household Fire Warning
System installations, the speaker must be mounted indoors for best
audibility. Also, for UL installations, use only one speaker. NOTE: Before
connecting sounding devices please consult their specifications for proper
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...