XL-1S Hookup and Installation Instructions
6–2
The system is armed at this time with all programmed delay zones instant; this eliminates
the exit/entry time delays. NOTE: INSTANT arming is ALWAYS enabled (see question #05,
location 4).
Stay/Instant Arming
TO ARM: Press the INSTANT then STAY buttons and a four-digit user code.
The INSTANT STAY mode will arm the system with the characteristics of both the
INSTANT and STAY modes. The system will be armed with the interior zones bypassed and
the delay zones instant.
LED keypads will have the ARMED, STAY and INSTANT LEDs lit.
LCD keypads will display:
ON: STAY INSTANT
Disarming
TO DISARM: Press any valid four- (4) digit user code and ARMED LED will extinguish.
If an alarm condition exists or had occurred while the system was armed, the zone LED(s)
and the READY LED will be blinking rapidly. This ALARM MEMORY condition can be
cleared by entering a valid user code or using the asterisk (*) key.
Reset
After an alarm occurs, the system enters alarm memory mode either after bell time-out or by
a user entering a valid user code silencing the bell and keypad buzzer. Alarm memory and
communications failure can be cleared by entering a valid user code. If a fire alarm
occurs, then clearing alarm memory resets the smoke detectors for approximately 8 seconds.
In addition, you can use the * key to act as a reset in addition to using a valid user
code for clearing Fire Alarms Only. THIS OPTION IS ALWAYS ENABLED.
Bypass
Bypassing is performed to temporarily exclude zones that are faulty or not ready from
activating the system.
Press the BYPASS button followed by any valid four- (4) digit user code, followed a
number 1-4, which represents the respective zone to be bypassed.
EXAMPLE: BYPASS ZONE 2 (Assume user code of 1234)
BYPASS 1234 2
Subsequent bypasses can be made by pressing the BYPASS button followed by another zone
number within a ten second period. After this ten-second period it will be necessary to enter
the entire command including the user code.
After a successful bypass the keypad sounder will sound the acknowledge beep, and the
respective zone LED will WINK SLOWLY.
The bypass rules are:
•
FIRE zones cannot be bypassed
•
24-hour zones can be bypassed, however they CANNOT be unbypassed if they are violated.
•
Zones can only be bypassed while the system is disarmed, at which time visual indication
will be displayed.
•
Bypass signals are transmitted to the Central Station UPON ARMING if a bypass code has
been programmed.
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...