REMOTE COMMUNICATIONS RING COUNT - is the number of rings for the control
panel to pickup for a remote communications session. This should be selected to a value that
does not interfere with normal operation of the panel location. The default value is 12 rings.
NOTE: A value of 0 rings means that remote programming will be disabled. Select from
the choices above.
SYSTEM DIALER DELAY - If selected, all controlled zones will have a 15 second dialer
delay, allowing the user to ABORT the CS transmission. If not selected, any alarm condition
will result in an immediate transmission that cannot be aborted. NOTE: For UL
installations this option must not be selected.
TRANSMIT ZONE RESTORE - If enabled, this option enables the transmission of zone
restores along with system restores (AC loss, Low Bat, etc.). If not enabled, the ONLY
restores transmitted will be the system restores (see question #18, location 2.
Question 07, L3
Trigger #1 Output
Default = 0
The smoke power terminals (12 & 13) or P1, T1 can be used as trigger #1 output. If a fire
zone requiring fire verification is used in the system, the trigger should be programmed as
“0”. If the fire device does not need a power reset, or no fire zone type is selected, the trigger
can be programmed as shown in the Trigger Types Chart. NOTE: Smoke Power Output can
only be enabled for trigger #1.
Question 07, L4
Trigger #2 Output
Default = 5
A secondary Trigger output can be obtained from P1, T2. The following Trigger Type Chart
shows the valid entries.
Digit
TRIGGER TYPE DEFINITION
DESCRIPTION OF OPERATION
0
Smoke Power Output (Trigger #1 Only)
Used in Fire Verification to reset smoke power
1
Fire Bell ON
Follows Fire Bell Timer
2
Burglary Bell ON
Follows Burglary Bell Timer
3
Telephone Line Seizure
Follows Line Seizure Relay when dialer is activated
4
Ready
Follows Ready LED; used for keyswitch
5
Armed
Follows Armed LED; used for keyswitch
6
Exit Time
ON during exit time
7
Entry Time
ON during entry time
8
Fire Only Latch
ON w/Fire Bell, OFF w/code
9
Burglary Only Latch
ON w/Burglary Bell, OFF w/code
A
Strobe
ON steady w/Burglary Bell, Pulse w/Fire Bell
B
Panic Alarm
Zone 5 (Hardwired Panic): ON w/alarm, OFF w/code
C
Shock Asterisk Reset
Asterisk "
✴
" activates for 2-6 seconds
D
Shock Code Reset
Normally sinking current: floats when armed for 2-6 sec.
E
Duress
Pulses for 2-6 seconds following entry of Duress code
Unless otherwise specified, the trigger output is normally floating and actively sinks on activation.
QUESTION 08
ACCOUNT NUMBER 1
DEFAULT = 1234
Enter the three- (3) or four- (4) digit subscriber account number for Central Station phone
number 1 in locations L1-L4. If a three- (3) digit number is used then enter an A in location
L4. Valid entries are 0-9, and B-F. The value A is interpreted as the null value for account
numbers.
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...