Section 8 - System Programming
8–5
KEYPAD AUXILIARY
Digit
KEYPAD
PANIC
STAY MODE
DIALER DELAY
STAY MODE
BELL INSTANT
AUDIBLE
SILENT
C
9
9
D
9
9
9
E
9
9
9
F
9
9
9
9
NOTE: Keypad Fire and Keypad Auxiliary are always enabled. Auxiliary Audible/Silent
selection refers to keypad sounder only (not the bell). Keypad Fire is always Audible. Keypad
Panic is Audible or Silent based on quest. #04, location 4.
STAY MODE DIALER DELAY - If selected this will give the system an additional delay as
follows: When the system is armed in the STAY mode, any control zone alarm (delay,
interior, and perimeter) will cause the dialer to be delayed by 40 seconds. A delay zone
will first follow the entry delay and then the 40 second delay. Also, during the 40-second
dialer delay the keypad sounder will be activated and the bell depending on whether it is
selected (see STAY MODE BELL INSTANT). When the system is not armed in the STAY
mode, the 40-second delay is disabled. If not selected, the 40-second delay during the STAY
mode will be disabled.
STAY MODE BELL INSTANT - This is selected in conjunction with the STAY MODE
DIALER DELAY option. If selected, the bell will sound instantly during the 40-second delay.
If not, the bell will also follow a 40-second delay.
Question 05, L2
Misc Options
Default = 2
Enter the digit from the table below in location L2. NOTE: The checkmark highlights which
options are selected.
ZONE 7 INPUT
PANIC
AC LINE
FREQUENCY
Digit
AUDIBLE
SILENT
KEYSWITCH
50 HZ
60 HZ
QUICK
COMMANDS
ENABLED
0
9
9
1
9
9
2
9
9
4
9
9
9
5
9
9
9
6
9
9
9
8
9
9
9
9
9
A
9
9
C
9
9
9
D
9
9
9
E
9
9
9
ZONE 7 INPUT: PANIC or KEYSWITCH - This option determines whether connections 5
& 7 on the control panel will be used as a panic input (audible or silent) or a keyswitch input.
NOTE: If keyswitch is selected and the transmission code sends a user code, then user code
#7 will be transmitted.
AC LINE FREQUENCY - This selects which AC input frequency (60 HZ or 50 HZ) is
present for the AC based system Clock.
Question 05, L3
CS Test Time Interval
Default = 7
If CS Test Report is enabled, this option determines the test time interval. NOTE: The
checkmark highlights which options are selected.
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...