Section 8 - System Programming
8–11
INTERIOR - All interior zones have exit delay time upon system arming. Furthermore, all
interior zones will have entry delay time if a delay zone is violated first. If this zone is
violated first however, it will generate an immediate alarm. Interior zones are bypassed if
Bypass In Stay is selected. Interior zones employ the Exit Error Warning feature described
in the note below.
PERIMETER - This zone type (sometimes known as INSTANT) will generate an alarm
when violated while the system is armed.
EXIT ERROR WARNING - At the end of exit time a 1-second window is started. If
any delay or interior zones are violated after arming within this window (exit time
expires and entry time starts) the burglary bell and keypad sounder will be turned
on forcing the user to enter their code preventing a false alarm transmission. This
helps avoid the common false alarms that take place after arming the system.
Burglary Zone Options
RESTORE - This option is selected for all burglary zones by enabling the restore report code
(question 18, location 2) and enabling transmit zone restores in question #07, location 2. The
programmed restore code will be reported upon bell cutoff. The restore code will also be
reported if the system is disarmed during an alarm. NOTE: Restore is not selectable by zone.
BYPASS IN STAY - This option allows zones to be bypassed when the system is armed in
the STAY mode.
CHIME - If this option is selected the keypad sounder will annunciate for 1 second when this
zone is violated in the disarmed mode.
DIALER DELAY - If this option is selected (quest. #07, location 2), then the system
(burglary zones only) will allow a 15 second delay before dialing, allowing the end user to
ABORT the transmission. If this option is not selected, any alarm condition will result in an
immediate transmission that cannot be aborted.
UL
For UL installations dialer delay may not be used.
DAY FEATURE - If a zone with this option is violated while the system is DISARMED, the
keypad sounder and zone LED will pulse for as long as the violation remains and the panel
will dial 15 seconds after the violation of the zone. In addition, the SYSTEM TROUBLE
CODE will be transmitted to the central station. THE SOUNDER CAN BE SILENCED
through entry operation of any valid user code. While the system is armed, a DAY zone will
act as an alarm when violated.
FAST ZONE - If enabled, the zone response will be 10 msec. If not selected, it will be 280
msec.
24 Hour Zones
Zones 1-4 can be programmed for any one of the following 24-hour zone types:
24 HOUR ZONES
ZONE TYPE
ZONE OPTIONS
L1L2
Digits
24 HR.
ALARM
FIRE
24 HR.
TROUBLE
AUDIBLE
SILENT
81
9
9
82
9
9
84
9
ALWAYS AUDIBLE
89
9
9
8A
9
9
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...