![background image](http://html1.mh-extra.com/html/fbii/xl-1s/xl-1s_hookup-and-installation-instructions_547073044.webp)
XL-1S Hookup and Installation Instructions
8–10
QUESTION 09
ACCOUNT NUMBER 2
DEFAULT = AAAA
Enter the three- (3) or four- (4) digit subscriber account number for Central Station phone
number 2 in locations L1-L4. If a three- (3) digit number is used then enter an A in location
L4. Valid entries are 0-9, and B-F. The value A is interpreted as the null value for account
numbers. If the second phone number is not used this question can be left as factory
defaulted.
THIS ACCOUNT NUMBER MUST BE ENTERED IF YOU HAVE PROGRAMMED A
SECOND RECEIVER PHONE NUMBER FOR BACKUP OR SPLIT REPORTING.
Zone Programming
Questions 10-13 represent all the options related to programmable zones 1-4. Each question
contains four (4) locations L1-L4. The first two locations (L1 & L2) define the zone type and
options. The second two locations (L3 & L4) define the alarm code transmitted to the Central
Station for that zone.
Zone Types
Zones 1-4 can be programmed for any one of the following zone types:
BURGLARY (CONTROLLED) ZONES
ZONE TYPE
ZONE OPTIONS
L1L2
Digits
INSTANT
(PERIMETER)
DELAY
(EXIT/ENTRY)
INTERIOR
FOLLOWER
CHIME
DAY
BYPASS
IN STAY
FAST
ZONE
10
9
NONE(INSTANT ZONE W/O OPTIONS)
11
9
9
12
9
9
13
9
9
9
14
9
9
15
9
9
9
18
9
9
19
9
9
9
1A
9
9
9
1B
9
9
9
9
1C
9
9
9
1D
9
9
9
9
20
9
NONE (DELAY ZONE W/O OPTIONS)
21
9
9
24
9
9
25
9
9
9
40
9
NONE (INTERIOR ZONE W/O OPTIONS)
41
9
9
44
9
9
45
9
9
9
48
9
9
49
9
9
9
4C
9
9
9
4D
9
9
9
Burglary (Controlled) Zones
DELAY - This is the industry standard exit/entry zone. When the system is armed exit time
begins. After exit expires, any subsequent violation of this zone will begin entry time. If the
system is not disarmed within the programmed entry time an alarm will occur. The keypad
sounder will annunciate steadily during entry time, unless there had been an alarm
condition, at which time it will pulse. Delay zones will activate instantly when the system is
armed using the STAY/INSTANT mode if enabled. Delay zones employ the Exit Error
Warning feature described in the note below.
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...