![FBII XL-1S Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/fbii/xl-1s/xl-1s_hookup-and-installation-instructions_547073048.webp)
XL-1S Hookup and Installation Instructions
8–14
offset of 7 hours. Enter hours and minutes in hexadecimal. The valid range for hours is 01 -
18 (24 hours) and the valid range for minutes is 01 - 3C (60 minutes).
QUESTION 15
CS CODES for AMBUSH and AC LOSS
DEFAULT = AAAA
There are 4 locations L1-L4 in this question as follows:
Question 15, L1 & L2 - Ambush Code
Default = AA
If an ambush code is defined, then user number 6 is the ambush code. The same rules
apply here regarding dialer format. If transmission is not desired, then program AA in
locations L1 & L2. NOTE: AMBUSH transmissions are immediate and not abortable.
Question 15, L3 & L4 - AC Loss Code
Default = AA
The same rules apply here regarding dialer format. If transmission is not desired, then
program AA in locations L3 & L4. NOTE: AC LOSS is reported 15 minutes after
detection.
QUESTION 16
CS CODES for PANIC and LOW BATTERY
DEFAULT = 22AA
There are 4 locations L1-L4 in this question.
Question 16, L1 & L2 - Panic Code
Default = 22
The same rules for programming regarding dialer format apply here. If transmissions are
not desired, then program AA in locations L1 & L2. NOTE: PANIC transmissions are
immediate and not abortable.
Question 16, L3 & L4 - Low Battery Code
Default = AA
The same rules for programming regarding dialer format apply here. If transmissions are
not desired, then program AA in locations L3 & L4. LOW BATTERY transmissions will
be reported 4 minutes after detection. LOW BATTERY RESTORE CODE will be reported
WITHIN 4 minutes after detection of GOOD BATTERY condition.
QUESTION 17
CS CODES for OPEN/CLOSE and CS TEST
DEFAULT = AAAA
There are 4 locations L1-L4 in this question.
Question 17, L1 - Opening Code
Default = A
Question 17, L2 - Closing Code
Default = A
L1 is the single digit OPENING CODE. L2 is the single digit CLOSING CODE. Entry of
AA into these two locations means that openings and closings are not desired. If a dialer
format other than standard is programmed then the second digit transmitted will be the
user number.
Question 17, L3 & L4 - CS Test Code
Default = AA
L3 - L4 is the CS Test CODE. Entry of AA means that CS Test is not enabled. If CS Test
code is selected then ANY valid transmission will reset the CS Test timer.
QUESTION 18
CS CODES for BYPASS, RESTORE, TROUBLE and CANCEL
DEFAULT = AAF8
There are four (4) locations L1 - L4 in this question.
Question 18, L1 - Bypass Code
Default = A
L1 is the single digit system BYPASS CODE that will be reported to the central station if
a zone is bypassed, UPON ARMING. Entry of an A means that bypasses are not
transmitted. If a two digit dialing format has been selected then the Bypass code will be
followed by the programmed second digit of the zones code.
Question 18, L2 - Restore Code
Default = A
L2 is the single digit system RESTORE CODE reported to the central station. This is the
system restore code for AC loss, Low Bat, etc. Restores will be ALSO be reported for all
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...