Section 6 - System Operations
6–3
Zones that are bypassed are not protected when the system is armed.
Auto Unbypass
All burglary zones which are bypassed can be automatically unbypassed upon
system disarm, assuming no other zone(s) had been in alarm. 24-hour zones, which
have been bypassed, will be unbypassed only if they are normal.
THE AUTO-UNBYPASS FEATURE IS ALWAYS ENABLED.
Manual Unbypass
This function removes an existing bypass from a currently bypassed zone. The procedure is
the same as bypass.
User Code Programming
User codes can be entered or modified directly through the keypad. The system contains up
to six user codes (4 digits each) with the following applications:
USER
NUMBER
APPLICATION
DEFAULT
CODE
1
Master User (see note 1)
1234
2
Normal User
NULL
3
Normal User
NULL
4
Normal User
NULL
5
Normal User
NULL
6
Ambush (see note 2)
NULL
NOTES: Only the master user (user number 1) can program or modify other users.
Therefore, do not misplace this code. Should you misplace you must perform a user code
default. Refer to the Installer Modes section.
1. User Number 1 - programs all user codes (1-6); cannot be deleted.
2. User Number 6 - can be programmed as an ambush code if there is an ambush CS
transmission code programmed into question #16, locations 1 & 2. In this mode, entry of
the user #6 code will ARM or DISARM the system and transmit the ambush code to the
Central Station. Furthermore if opening/closing by user reporting is programmed, user
number 6 will be reported along with the ambush code. If no CS code is defined in
question #16, then user number 6 will be a normal user code.
To Add Or Change Users:
[CODE] [USER] [USER #] [USER ID]
Where:
[CODE]
Press CODE button
[USER]
Enter Master User ID code (user #1)
[USER #]
Press Desired user to be programmed (1-6)
[USER ID]
Enter Four-digit user code. Valid digits are 0-9
Example: Define user #3 with an ID of 7493. (Assume master user code is 1234).
CODE 1234 3 7493
An acknowledgment sound (steady tone) verifies a successful user code
programming. A negative acknowledgment sound (4 short tones) indicates
unsuccessful programming.
If additional user programming is necessary, repeat the procedure listed above. If a dialing
format is programmed which transmits opening/closing by user ID, each user will report the
respective user number.
Содержание XL-1S
Страница 8: ...viii ...
Страница 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Страница 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Страница 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Страница 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Страница 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Страница 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Страница 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Страница 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Страница 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Страница 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Страница 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Страница 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...