Programming
page 5-22
QFE
FD8420 issue02_F
5.3.9
The Outputs Menu
Led
-
This menu item is only of use to a customer who is using
the Pot’s and Switches software, which is covered by another publication (FD50E3 & FD50EJ).
K1
-
This menu item allows the customer to program the K1
relay (section
2.7.3
of Electrical Installation). At the bottom of the submenu is a list of
programming short cuts which will set up the relay for the user. Below is a list of the short
cuts with a description of when they energise the relay;
Run Relay
-
Usually for controlling the main contactor, energises whilst the
unit is running.
Bypass Relay
-
Usually for controlling the bypass contactor, energises when
the unit reaches TOR.
Alarm
-
Energises when an Alarm condition is present.
CurrentLimitng
-
Energises when the unit is current limiting.
OvldIntgrating
-
Energises when the QFE’s overload is integrating.
Stall
-
Energises when the motor is stalling.
Cooling
-
Energises when the QFE is cooling (start inhibited).
Enable Status
-
Energises when the QFE is enabled.
A worked example showing how to program a relay is given in section
5.4.11
.
K2
-
This menu item allows the customer to program
the K2 relay (section
2.7.3
of Electrical Installation). At the bottom of the submenu is a list of
programming short cuts which will set up the relay for the user (see above). A worked
example showing how to program a relay is given in section
5.4.11
.
K3
(QFE+)
-
This menu item allows the customer to program
the K3 relay (section
2.7.4
of Electrical Installation). At the bottom of the submenu is a list of
programming short cuts which will set up the relay for the user (see above). A worked
example showing how to program a relay is given in section
5.5.3
.
K4
(QFE+)
-
This menu item allows the customer to program
the K4 relay (section
2.7.4
of Electrical Installation). At the bottom of the submenu is a list of
programming short cuts which will set up the relay for the user (see above). A worked
example showing how to program a relay is given in section
5.5.9
.
Analogue o/p 1
(QFE+)
-
This menu item allows the customer to program
the first analogue output (section
2.7.4
of Electrical Installation). A worked example showing
how to program an analogue output is given in section
5.5.10
.
Analogue o/p 2
(QFE+)
-
This menu item allows the customer to program
the second analogue output (section
2.7.4
of Electrical Installation). A worked example
showing how to program an analogue output is given in section
5.5.10
.
5.3.10
The Parameters Menu
This menu contains a number based, complete listing of all parameters, menu items and
their values. Those parameters and menu items which can be written to, can be written to
here as well as in the main text-based menu section. The parameters are listed in numerical
order, and an explanation of what each parameter does, it’s default value, units etc..., can be
found in ‘The_5MC_Parameter_List’, a document on the website.
Содержание QFE Series
Страница 17: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Mechanical Installation FD841205_F...
Страница 18: ...Mechanical Installation QFE page 1 2 FD841205_F...
Страница 26: ...Mechanical Installation QFE page 1 10 FD841205_F...
Страница 27: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Electrical Installation FD8413 issue03_F...
Страница 43: ...QFE page 2 19 Electrical Installation FD8413 issue03_F...
Страница 50: ...Electrical Installation QFE page 2 26 FD8413 issue03_F...
Страница 51: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Applications...
Страница 73: ...QFE page 3 25 Applications FD841405_F...
Страница 112: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Programming Guide FD8420 issue02_F...
Страница 158: ...page 5 47 Programming QFE FD8420 issue02_F This page is left intentionally blank...
Страница 181: ...Modbus page 6 4 5MC FD510007...