![Fairford Electronics QFE Series Скачать руководство пользователя страница 122](http://html1.mh-extra.com/html/fairford-electronics/qfe-series/qfe-series_manual_3218507122.webp)
page 5-11
Programming
QFE
FD8420 issue02_F
5.3
Using the Menus
This section gives a brief description of the individual menus and the functions that their
parameters perform.
5.3.1
The Applications Menu
This menu contains a list of typical applications for which a set of parameters have been
predefined by the manufacturer. This feature provides a quick and easy way of setting up
the unit. There are three exceptions to this list: the first menu item,
Settings
, provides
a brief report on the basic settings of the unit (see below
and section
5.4.6
); the second
menu item,
Default (keypad)
, provides a way of loading the default parameter values
with
Keypad Starting
as the choice for the starting option (see section
5.4.4
); the third
menu item,
Default Auto
, loads default parameter values and additionally turns on a
number of features from the Auto Features menu. Further details can be found in the
following documents, QFE Applications Data and the 5MC Bit Parameters.
Apart from these exceptions, the parameters that will be altered when one of the
typical applications ( small pump etc..) is selected are again listed in the documents QFE
Applications Data and the 5MC Bit Parameters which can be found on the website.
Settings report; below is a list detailing the report given by the
Settings
menu item.
When accessed it will display some information relevant to the QFE’s current state. The
messages are displayed in the order that they are listed below . A brief explanation of each
message is included (see section
5.4.6
on how to access this report).
V1.063 03/09/01
5MC V 55.11
Menu V1.017
Remote/
Keypad Starting
Full/
Full&Opt/
Start&Bypass/
Phase Loss Only
Small Pump
Temp/Alt Derated
This message shows the keypad software version number
and it’s release date .
This message gives the version number of the software in
the 5MC control board.
This message gives the version number of the navigating
menu.
This message indicates whether the Starting Parameter has
been set to keypad, or remote starting.
This message shows what protection mode has been set in
the Protection Parameter.
This next message will show what (if any) application has
been set from the Application menu (Small Pump is shown
as an example). If no application has been set then the display
will appear blank for a couple of seconds.
This message will be displayed if the unit has been derated
for temperature or altitude. If no derating has been set then
the display will appear blank for a couple of seconds.
Содержание QFE Series
Страница 17: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Mechanical Installation FD841205_F...
Страница 18: ...Mechanical Installation QFE page 1 2 FD841205_F...
Страница 26: ...Mechanical Installation QFE page 1 10 FD841205_F...
Страница 27: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Electrical Installation FD8413 issue03_F...
Страница 43: ...QFE page 2 19 Electrical Installation FD8413 issue03_F...
Страница 50: ...Electrical Installation QFE page 2 26 FD8413 issue03_F...
Страница 51: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Applications...
Страница 73: ...QFE page 3 25 Applications FD841405_F...
Страница 112: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Programming Guide FD8420 issue02_F...
Страница 158: ...page 5 47 Programming QFE FD8420 issue02_F This page is left intentionally blank...
Страница 181: ...Modbus page 6 4 5MC FD510007...