![Fairford Electronics QFE Series Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/fairford-electronics/qfe-series/qfe-series_manual_3218507103.webp)
FD8416 5MC Parameters
03 September 2003
55
55
55
55
Software
.
11
11
11
11
81
KICK PED 2
75
90
60
%
Read/Write
kickstart pedestal to use with the second parameter set
Edit in P Menu
Description
Hints
PN
Parameter Name
Default
Max
Min
Units
Type
Scaling
1
Std
82
KICK TIME 2
25
40
10
cycles
Read/Write
kickstart time to use with the second parameter set
Edit in P Menu
Description
Hints
PN
Parameter Name
Default
Max
Min
Units
Type
Scaling
1
Std
83
DWELL 2
5
255
1
Secs
Read/Write
Dwell time to use with the second parameter set.
Edit in P Menu
Description
Hints
PN
Parameter Name
Default
Max
Min
Units
Type
Scaling
1
Std
84
STOP PED 2
10
60
10
%
Read/Write
Stop pedestal to use with the second parameter set
Edit in P Menu
Description
Hints
PN
Parameter Name
Default
Max
Min
Units
Type
Scaling
1
Std
85
STOP TIME 2
0
255
0
Secs
Read/Write
Stop timel to use with the second parameter set.
Edit in P Menu
Description
Hints
PN
Parameter Name
Default
Max
Min
Units
Type
Scaling
1
Std
86
Auto Config 2
6
255
0
flags
Read/Write
Auto configuration flags to use with the second parameter
set.
Edit in P Menu
Description
Hints
PN
Parameter Name
Default
Max
Min
Units
Type
Scaling
1
Std
87
UNDER CURRENT 2
0.125
1
0
x Ie
Read/Write
Under current level to use with the second parameter set.
Edit in P Menu
Description
Hints
PN
Parameter Name
Default
Max
Min
Units
Type
Scaling
0.03125
Std
88
UNDER CURRENT TIME 2
50
255
5
cycles
Read/Write
Under Current time to use with the second parameter set
Edit in P Menu
Description
Hints
PN
Parameter Name
Default
Max
Min
Units
Type
Scaling
1
Std
89
CURRENT LIMIT 2
4
7.96875
1
x Ie
Read/Write
Current limit value to be used with the second parameter set. Edit in P Menu
Description
Hints
PN
Parameter Name
Default
Max
Min
Units
Type
Scaling
0.03125
Std
Page 12 of 17
Содержание QFE Series
Страница 17: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Mechanical Installation FD841205_F...
Страница 18: ...Mechanical Installation QFE page 1 2 FD841205_F...
Страница 26: ...Mechanical Installation QFE page 1 10 FD841205_F...
Страница 27: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Electrical Installation FD8413 issue03_F...
Страница 43: ...QFE page 2 19 Electrical Installation FD8413 issue03_F...
Страница 50: ...Electrical Installation QFE page 2 26 FD8413 issue03_F...
Страница 51: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Applications...
Страница 73: ...QFE page 3 25 Applications FD841405_F...
Страница 112: ...QFE Soft Start Motor Controller Technical Data for the QFE and QFEplus Programming Guide FD8420 issue02_F...
Страница 158: ...page 5 47 Programming QFE FD8420 issue02_F This page is left intentionally blank...