ADVANCED programming
Default
O1
OUTPUT O1 CONFIGURATION
0
= DISABLED
1
= GONG
2
= ERROR
3
= BATTERY OPERATION
4
= EMERGENCY ACTIVE
5
= TEST
6
= DOOR NOT CLOSED
7
= DOOR OPENED
8
= DOOR OPENING
9
= courtesy LIGHT
10
= INTRUSION ACTIVE
11
= CLOSING SAFETY ACTIVE
12
= SAFETIES ACTIVE
EP
= value set using KP EVO, not displayable
1
1C
TYPE OF CONTACT OUTPUT O1
Not displayed if output is disabled
nO
= NO contact
nC
= NC contact
nO
O2
OUTPUT O2 CONFIGURATION
See parameter
O1
.
5
2C
TYPE OF CONTACT OUTPUT O2
Not displayed if output is disabled
nO
= NO contact
nC
= NC contact
nC
CF
CLOSING FORCE
Adjustable from
1
(minimum) to
10
(MAX)
5
OF
OPENING FORCE
Adjustable from
1
(minimum) to
10
(MAX)
10
tF
FORCE TIME
Regulates the maximum thrust time before an obstacle
is recognised during opening/closing
Adjustable from
1
to
30
tenths of a second
15
Hc
ANTI-INTRUSION
The door resists attempts to open it manually
no
= disabled
Y
= enabled
no
cS
SCP (SELECTABLE CLOSE POWER)
Increases the force with which the door pushes in the
final section of the closure. It is useful to activate
this function if there is high friction, if the seals are
particularly rigid or if locks have a stiff latch.
no
= disabled
Y
= enabled
no
!
Because activating the SCP function also reduces the
sensitivity of the electronic anti-crushing system in
the final section of closing, DO NOT activate the SCP
function in "low energy" mode.
10
ADVANCED programming
ADVANCED programming
Default
S1
EXTERNAL SELECTOR POSITION 1
Defines the function of the external selector when in
position 1
0
= DISABLED
1
= NIGHT
2
= OPEN
3
= EXIT ONLY
4
= MANUAL
1
S2
EXTERNAL SELECTOR POSITION 2
Defines the function of the external selector when in
position 2
See parameter
S1
.
4
P1
INPUT S1 CONFIGURATION
no
= DISABLED
1
= EXTERNAL OPEN (NO)
4
= INTERNAL OPEN (NO)
7
= AUTOMATIC OPEN (NO)
8
= SEMIAUTOM. OPEN (NO)
10
= KEY (NO)
11 = PARTIAL OPEN (NO)
20
= CLOSING SAFETY (NC)
21
= OPENING SAFETY (NC)
30
= EMERGENCY OPEN (NO)
31
= EMERGENCY OPEN WITH MEMORY (NO)
34
= EMERGENCY CLOSE (NO)
35
= EEMERGENCY CLOSE WITH MEMORY (NO)
40
= ALWAYS OPEN (NO)
41
= EXIT ONLY (NO)
42
= ONLY IN (NO)
43
= NIGHT (NO)
44
= MANUAL (NO)
45
= PARTIAL (NO)
46
= INTERBLOCK ON (NO)
60
= TIMER (NO)
default contact type indicated in brackets
EP
= value set using KP EVO, not displayable
no
IF
TEST (FAIL SAFE) INPUT S1
Displayed only for functions
20
and
21
Y
= test enabled
no
= test not enabled
no
P2
INPUT S2 CONFIGURATION
See parameter
P1
.
no
2F
TEST (FAIL SAFE) INPUT S2
Displayed only for functions
20
and
21
Y
= test enabled
no
= test disabled
no