5. MECHANICAL INSTALLATION
F
CARRY OUT THE FOLLOWING OPERATIONS WITH THE
ELECTRICITY SUPPLY DISCONNECTED.
!
The installation must conform to Standard EN 16005.
Mark off the work site and prohibit access/transit.
When installation is complete, make sure that you
have not left any tools on top of the door operator.
The installation procedure below refers to a door
with hinges on the left, as seen from the automation
side.
If the hinges are on the right, the installation
should be carried out as a mirror image.
RISKS
PERSONAL PROTECTIVE EQUIPMENT
5.1 CABLE INLET A951
The A951 is designed for cables to enter either from the
functions selector side (
4
) or from the back (
5
).
The cable inlet area is indicated on the template
provided.
When wiring the system, allow at least 45 cm of ca-
ble from the cable inlet area to connect to the door
operator.
5.2 FASTENING THE A951
1. Identify the correct installation configuration and
the relative template from those provided.
2. Position the template and secure it temporarily
using adhesive tape (
6
).
In order to position it correctly:
- Match up the axis of the hinges with the vertical
reference mark on the template.
- Align the upper edge of the door with the horizontal
reference mark on the template, according to the type
of hub (standard or with an extension) used.
3. Mark the holes to be drilled on the architrave and
the door using a pencil or the tip of a screwdriver.
There are 9 points, 6 black and 3 white central ones
arranged in 3 vertical rows on the fixing plate tem-
plate. At least 6 points, normally the black ones,
should be used. The central white points should be
used in addition or as an alternative to ensure that
there are at least 2 fixing points for each vertical row.