9.3 AUTOMATION STATUS CHECK
The current status of the automation can be checked
on the board or via the KP EVO.
ON THE BOARD
The display of the A951, if you are not in programming
mode, displays the code that indicates the status of the
automation (
16
).
ON THE KP EVO
Go to menu 2.5.10. The display shows information
regarding the status of the automation.
41
Date and time missing
- Reset date/time via the KP EVO
42
Clock battery discharged or missing
44
Emergency active (including command memory)
45
Timer active
46
Timer function in progress
48
Night mode operation
49
Manual mode operation
50
Partial mode operation
51
Obstacle detected during closure
52
Obstacle detected during opening
53
Number of maintenance cycles on E
2
prom corrupted
- Perform reset.
- If the alarm persists, replace the Logic board
56
Battery operation
58
Searching for strike on closing
60
Maintenance requested
61
KP EVO fault
- Check that the correct device is connected and check the
connections.
- If the alarm persists, update the firmware
- If the alarm persists, replace the Logic board
63
Intrusion in progress
65
Set-up in progress
68
TEST alarm (only if the “test error” parameter is enabled)
- Check the operation of the connected devices
- If the alarm persists, replace the device
- If the alarm persists, replace the Logic board
In this condition, the door moves at a slower speed.
69
Door opened by a semi-automatic command
71
Slave Intercom mode
72
Intercom alarm
- Check the connections
- Check the ID
- If the alarm persists, replace the Logic board
73
Slave Error / Alarm
74
Interlock alarm
- Check the connections
- Check the ID
- If the alarm persists, replace the Logic board
76
Radio code memory full
80
Non-standard programming
83
BUS 2easy call in progress
84
BUS 2easy in sleep
85
BUS 2easy interrogation in progress
86
BUS 2easy disconnection in progress
16
System status
00
CLOSED
01
OPENING
02
OPEN
03
PAUSE
04
NIGHT PAUSE
05
CLOSING
06
EMERGENCY ACTIVATE
07
MANUAL
08
NIGHT
11
STOP
12
SECURITIES TEST
13
ERROR
L0
waiting for SET-UP to start
L1
SETUP phase 1: closing stop search
L2
SETUP phase 2: opening stop search
9.4 WARNINGS
Alerts provide information regarding the status or
current phase of the automation and errors that do not
prevent it from operating. It is possible to check any
current alerts on the board or via the KP EVO.
ON THE BOARD
Whilst the A951 is displaying the status of the auto-
mation, press the + and - buttons simultaneously:
Al
appears on the display followed by any identification
codes (
17
).
ON THE KP EVO
Go to menu 4 to view the list of current alerts.
If there is at least one alert, an icon appears on the
home screen (
34
).
17
Warnings
Содержание A951
Страница 1: ...A951 EN16005...
Страница 65: ......