6.9 OUTPUTS CONFIGURATION (J5)
The outputs on terminal board J5 (O1 and O2) can be
configured on the A951 or via the KP EVO using the
following functions.
Each input can be set to NC or NO according to the
device connected to it.
■
DISABLED
No associated function.
■
GONG
The output is activated and deactivated at 1-second
intervals when the safety devices are in use.
■
ERROR
The output is activated if there is an error.
■
BATTERY
The output is activated when operating with the
battery.
■
EMERGENCY ACTIVATE
The output is activated when an EMERGENCY is
triggered.
■
TEST
The output commands a TEST (FAIL SAFE) on the
inputs that are configured as safety devices on which
the option of running a TEST before movement has
been enabled.
■
DOOR NOT CLOSED
The output remains active until the door is closed.
■
DOOR OPEN
The output remains active as long as the door is open.
■
DOOR MOVING
The output remains active as long as the door is
moving.
■
LIGHT
The output is activated, for
a programmable length of
time, w
hen the door is opened in NIGHT mode.
■
INTRUSION ACTIVE
The output is activated when an intrusion is in progress
(i.e. when an unexpected movement of the door from
its closed position is detected).
■
CLOSING SAFETY DEVICE
The output is activated when a closing safety device
is active.
■
SAFETIES
The output is activated when a closing or opening
safety device is active.