A951
60
532081 - RevA
54
A951
MASTER
ID=1
A951
SLAVE
ID=2
A951
SLAVE
ID=15
A951
SLAVE
ID=3
55
Tr
ansla
tion of the original instruc
tions
ENGLISH
A951
Master interlock
ID=1
A951
Slave interlock
ID=3
15.1 INTERMODE
54
shows the IDs to assign to the A951 units in
the network.
The system consists of a Master unit and a maximum
of 14 Slave units. The A951 Master unit is the only one
on which the operating mode should be set, which is
then also applied immediately to all the Slave units.
With INTERMODE, it is not possible to change the
operating mode of an individual unit.
The A951 Master must be assigned ID1 and the Slave
units with IDs from 2 to 14.
15.2 INTERLOCK
55
shows the IDs to assign to the A951 units in
the network.
Either of the two units can be designated as the Master
and the other as the Slave. In
INTERLOCK mode, one
door can open only if the other is closed. The available
variations are shown below.
If the PARTIAL mode is associated with INTERLOCK,
only the Master leaf opens.
Connect the devices and carry out the programming
and Set-up on the individual A951 units before con-
figuring the INTERLOCK using the KP EVO.
Select
on the Master unit to activate the
INTERLOCK.
Содержание A951
Страница 1: ...A951 EN16005...
Страница 65: ......