show eaps
ExtremeWare 7.5 Command Reference Guide
1425
State:
On a transit node, the command displays one of the following states:
•
Idle—The EAPS domain has been enabled, but the configuration is not
complete.
•
Links-Up—This EAPS domain is running, and both its ports are up and in
the FORWARDING state.
•
Links-Down—This EAPS domain is running, but one or both of its ports are
down.
•
Preforwarding—This EAPS domain is running, and both of its ports are up,
but one of them is in a temporary BLOCKED state.
On a master node, the command displays one of the following states:
•
Idle—The EAPS domain has been enabled, but the configuration is not
complete.
•
Init—The EAPS domain has started but has not yet determined the status
of the ring. The secondary port is in a BLOCKED state.
•
Complete—The ring is in the COMPLETE state for this EAPS domain.
•
Failed—There is a break in the ring for this EAPS domain.
•
[Failtimer Expired]—When the failtimer expires and it’s action is set to
send-alert, this flag is set. This flag indicates there is a misconfiguration or
hardware problem in the EAPS ring. The EAPS master node will continue
to remain in COMPLETE or INIT state with it’s secondary port blocking.
[Running: …]
•
Yes—This EAPS domain is running.
•
No—This EAPS domain is not running.
Enabled:
Indicates whether EAPS is enabled on this domain.
•
Y—EAPS is enabled on this domain.
•
N—EAPS is not enabled.
Mode:
The configured EAPS mode for this switch: transit (T) or master (M).
Primary/Secondary port:
The port numbers assigned as the EAPS primary and secondary ports. On the
master node, the port distinction indicates which port is blocked to avoid a
loop.
Port status:
•
Unknown—This EAPS domain is not running, so the port status has not yet
been determined.
•
Up—The port is up and is forwarding data.
•
Down—The port is down.
•
Blocked—The port is up, but data is blocked from being forwarded.
Tag status:
Tagged status of the control VLAN:
•
Tagged—The control VLAN has this port assigned to it, and the port is
tagged in the VLAN.
•
Untagged—The control VLAN has this port assigned to it, but the port is
untagged in the control VLAN.
•
Undetermined—Either a VLAN has not been added as the control VLAN to
this EAPS domain or this port has not been added to the control VLAN.
Hello Timer interval:
The configured value of the timer in seconds, specifying the time that the
master node waits between transmissions of health check packets.
Fail Timer interval:
The configured value of the timer in seconds, specifying the time that the
master node waits before the failtimer expires.
Содержание ExtremeWare 7.5
Страница 358: ...358 ExtremeWare 7 5 Command Reference Guide Commands for Configuring Slots and Ports on a Switch ...
Страница 402: ...402 ExtremeWare 7 5 Command Reference Guide VLAN Commands ...
Страница 470: ...470 ExtremeWare 7 5 Command Reference Guide QoS Commands ...
Страница 489: ...show nat ExtremeWare 7 5 Command Reference Guide 489 Platform Availability This command is available on all platforms ...
Страница 490: ...490 ExtremeWare 7 5 Command Reference Guide NAT Commands ...
Страница 826: ...826 ExtremeWare 7 5 Command Reference Guide Commands for Status Monitoring and Statistics ...
Страница 1011: ...enable ssh2 ExtremeWare 7 5 Command Reference Guide 1011 Platform Availability This command is available on all platforms ...
Страница 1026: ...1026 ExtremeWare 7 5 Command Reference Guide Security Commands Platform Availability This command is available on all platforms ...
Страница 1090: ...1090 ExtremeWare 7 5 Command Reference Guide Security Commands ...
Страница 1099: ...download bootrom ExtremeWare 7 5 Command Reference Guide 1099 Platform Availability This command is available on all platforms ...
Страница 1386: ...1386 ExtremeWare 7 5 Command Reference Guide Wireless Commands ...
Страница 1428: ...1428 ExtremeWare 7 5 Command Reference Guide EAPS Commands Platform Availability This command is available on all platforms ...
Страница 1430: ...1430 ExtremeWare 7 5 Command Reference Guide EAPS Commands Platform Availability This command is available on all platforms ...
Страница 1436: ...1436 ExtremeWare 7 5 Command Reference Guide EAPS Commands ...
Страница 1466: ...1466 ExtremeWare 7 5 Command Reference Guide STP Commands Platform Availability This command is available on all platforms ...
Страница 1472: ...1472 ExtremeWare 7 5 Command Reference Guide STP Commands Platform Availability This command is available on all platforms ...
Страница 1476: ...1476 ExtremeWare 7 5 Command Reference Guide STP Commands Platform Availability This command is available on all platforms ...
Страница 1479: ...show stpd ports ExtremeWare 7 5 Command Reference Guide 1479 Platform Availability This command is available on all platforms ...
Страница 1530: ...1530 ExtremeWare 7 5 Command Reference Guide ESRP Commands Platform Availability This command is available on all platforms ...
Страница 1568: ...1568 ExtremeWare 7 5 Command Reference Guide ESRP Commands ...
Страница 1754: ...1754 ExtremeWare 7 5 Command Reference Guide IGP Commands Platform Availability This command is available on all platforms ...
Страница 1814: ...1814 ExtremeWare 7 5 Command Reference Guide IGP Commands Platform Availability This command is available on all platforms ...
Страница 1844: ...1844 ExtremeWare 7 5 Command Reference Guide IGP Commands ...
Страница 1930: ...1930 ExtremeWare 7 5 Command Reference Guide BGP Commands i Series Switches Only ...
Страница 2022: ...2022 ExtremeWare 7 5 Command Reference Guide IP Multicast Commands ...
Страница 2066: ...2066 ExtremeWare 7 5 Command Reference Guide IPX Commands i Series Platforms Only ...
Страница 2082: ...2082 ExtremeWare 7 5 Command Reference Guide ARM Commands BlackDiamond Switch Only ...
Страница 2094: ...2094 ExtremeWare 7 5 Command Reference Guide Remote Connect Commands ...
Страница 2106: ...2106 ExtremeWare 7 5 Command Reference Guide ATM Commands BlackDiamond 6800 Series Platforms Only ...
Страница 2174: ...2174 ExtremeWare 7 5 Command Reference Guide PoS Commands BlackDiamond Switch Only ...
Страница 2230: ...2230 ExtremeWare 7 5 Command Reference Guide T1 E1 and T3 WAN Commands Alpine 3800 Series Platforms ...
Страница 2336: ...2336 ExtremeWare 7 5 Command Reference Guide Power Over Ethernet Commands Summit 300 and 400 24p Switches and Alpine PoE Module ...
Страница 2372: ...2372 ExtremeWare 7 5 Command Reference Guide LLDP Commands ...
Страница 2422: ...2422 ExtremeWare 7 5 Command Reference Guide H VPLS Commands BlackDiamond Switch Only ...
Страница 2528: ...2528 ExtremeWare 7 5 Command Reference Guide MPLS Commands BlackDiamond Switch Only ...