Profiles for PHOENIX MIG/MAG systems
Profiles for the Profibus DP module
66
Item No.: 099-008225-EWM01
7.4.3
Compatible profile (switch position 2)
The module uses a data capacity of 10 bytes for input data and 11 bytes for output data.
The profile can be used to replace previously used BUSINTX10 Profibus interfaces. The profile is fully
compatible for this purpose.
Actuation data
Byte
no.
Bit no.
Function
Description
0 0 Start
Bit allocation:
0
1
Start signal to initiate the welding process
Signal stop on system
Signal start on system
0 1 User-defined
output
Bit allocation:
0
1
Switches the user-defined relay output on the bus
module
Relay not switched
Relay switched
0
2
Select welding mode
Bit allocation:
0
1
Select between normal/pulse welding
Normal welding active
Pulse welding active
0
3&4
Select operating mode
Bit allocation:
Bit1 Bit0
0 0
0 1
1 0
1 1
Select between non-latched/latched/special non-
latched/special latched
Non-latched operating mode
Latched operating mode
Special latched operating mode
Special non-latched operating mode
0
5
Machine program pre-
selection
Bit allocation:
0
1
The program is selected by the machine
Program 1 is permanently set
Programs 0-15 can be selected
0 6 Machine
JOB
pre-selection
Bit allocation:
0
1
Select the selection mode for JOBs
JOB pre-selection via operating panel (M31X)
JOB pre-selection from machine (field bus)
0
7
Error reset
Acknowledgement signal for system error
1
0
Gas test 1
Bit allocation:
0
1
Manual check of the process gas supply
Gas supply off
Gas supply on
1 1 Inching
Bit allocation:
0
1
Signal for wire inching function on the wire feed
drive
Inching off
Inching on
1 2 Reverse
inching
Bit allocation:
0
1
Signal for reverse wire inching function
Reverse inching off
Reverse inching on
1 3 WF switching (optional)
Bit allocation:
0
1
Switches between 2 wire drive units
WF case 1 is active
WF case 2 is active