Rx-PDO 1
Cob ID = 200h + address
Byte
no.
Bit no.
Function
Description
1 2 Reverse
inching
Bit allocation:
0
1
Signal for reverse wire inching function
Reverse inching off
Reverse inching on
1
3
Start auxiliary process
Bit allocation:
0
1
Start signal to initiate the auxiliary process
Auxiliary process is shut down
Auxiliary process is started
1 4 Error
reset
Bit allocation:
0
1
Acknowledgement signal for system error
Signal must have positive edge for
acknowledgement
1 5 User-defined
output
Bit allocation:
0
1
Switches the user-defined relay output
On the bus module
Relay not switched
Relay switched
1 6 JOB
mode
Bit allocation:
0
1
Signal activates the JOB mode function
JOB mode switched off
JOB mode active
1 7 Welding
simulation
Bit allocation:
0
1
Activates the Simulate Welding function
Simulation active
Simulation off
2 0-3
4-6
Program number specification
Reserved
Select a program number in the range 1-15
2
7
WF switching (optional)
Bit allocation:
0
1
Switches between 2 wire drive units
WF case 1 is active
WF case 2 is active
3
0-7
JOB number specification
Select a JOB number in the range of
1-255
4
0-7
I specification, low-byte
Specification of the welding current, the scaling is
always 100% dependent on the system current in
question:
Range: 0 to 0 x 7FFF
0 corresponds to RANGE-MIN
0 x 7FFF corresponds to the max. system current
5
0-7
I specification, high-byte
Specification of the welding current
6
0-7
WF cold wire specification,
low byte
Specification of the wire value
Range: 0 to 0 x 7FFF
0 corresponds to 0.00 m/min
0 x 7FFF corresponds to 10.0 m/min or 5.00 m/min
depending on the cold wire feed
7
-
WF cold wire specification,
high byte
Specification of the wire value