Profiles for TETRIX TIG and plasma systems
Profile on the Interbus Module
Item No.: 099-008225-EWM01
121
Byte
no.
Bit no.
Function
Description
10
0-7
Plasma gas specification, low-
byte
Specification of the plasma gas
Range: 0 to 0 x 7FFF
0 x 7FFF corresponds to 10.0 l/min
11 0-7 Plasma
gas
specification,
high-byte
Specification of the plasma gas
12
0-7
Shielding gas specification,
low-byte
Shielding gas specification
Range: 0 to 0 x 7FFF
0 x 7FFF corresponds to 20.0 l/min
13
0-7
Shielding gas specification,
high-byte
Shielding gas specification
14
0-7
Frequency specification, low-
byte
Specification of the frequency for thermal pulsing
Range: 0 to 0 x 7FFF
0 corresponds to 50 Hz
0 x 7FFF corresponds to 2500 Hz
15
0-7
Frequency specification, high-
byte
Frequency specification
16
0-7
Balance specification, low-
byte
Specification of the balance for thermal pulsing
Range: 0 to 0 x 7FFF
0 corresponds to 1%
0 x 7FFF 100%
17
0-7
Balance specification, high-
byte
Balance specification
18 & 19 0-7
Reserved
Process data
Byte
no.
Bit no.
Function
Description
0
0
I > 0
Bit allocation:
0
1
"Current flows" signal from process
No current flowing
Current flows, arc stationary
0
1
Ready for welding
Bit allocation:
0
1
Ready signal from process
System not ready
System is ready
0 2 Sticking
Bit allocation:
0
1
Wire sticking message from process
Wire is free
Wire sticks to the workpiece
0 3 Error
Bit allocation:
0
1
General fault message from process
No error
Fault occurred and not rectified
0 4 Collision
signal
Bit allocation:
0
1
Signals triggering of the collision protection
No collision
Collision