Profiles for PHOENIX MIG/MAG systems
Profiles for the Profibus DP module
62
Item No.: 099-008225-EWM01
7.4.2
Flexible profile (switch position 1)
The module uses a data capacity of 10 bytes for input data and 11 bytes for output data. The JOB mode
can only be activated via the jumper in this profile. The data is arranged so that data required on the
Profibus can be grouped via the module programming.
The program and JOB selection bits can be used to pre-select the actuation type for programs and JOBs.
Actuation data
Byte
no.
Bit no.
Function
Description
0 0 Start
Bit allocation:
0
1
Start signal to initiate the welding process
Signal stop on system
Signal start on system
0 1 Robot
ready
Bit allocation:
0
1
Safety signal for rapid shut-down
No ready message from robot, no start possible,
rapid shut-down carried out in the process
Robot ready message, start is possible
0
2
Select welding mode
Bit allocation:
0
1
Select between normal/pulse welding
Normal welding active
Pulse welding active
0
3
Select operating mode
Bit allocation:
0
1
Select between non-latched/special non-latched
Non-latched operating mode
Special non-latched operating mode
0
4
Machine program pre-
selection
Bit allocation:
0
1
The program is selected by the machine
Program 1 is permanently set
Programs 0-15 can be selected
0
5
Machine job pre-selection
Bit allocation:
0
1
Select the selection mode for Jobs
Job pre-selection via operating panel (M31X)
JOB pre-selection from machine (field bus)
0 6 WF switching (optional)
Bit allocation:
0
1
Switches between 2 wire drive units
WF case 1 is active
WF case 2 is active
0
7
Error reset
Acknowledgement signal for system error
1
0
Gas test 1
Bit allocation:
0
1
Manual check of the process gas supply
Gas supply off
Gas supply on
1 1 Inching
Bit allocation:
0
1
Signal for wire inching function on the wire feed
drive
Inching off
Inching on
1 2 Reverse
inching
Bit allocation:
0
1
Signal for reverse wire inching function
Reverse inching off
Reverse inching on