Operating problems, causes and remedies
Error messages on the system
126
Item No.: 099-008225-EWM01
10.2 Error messages on the system
The following error messages are output via the bus interface on the higher level control:
Error
number
(value)
Meaning Relevance
to system
Error can be reset
General
system
error
4
Wire supply error
PHOENIX/TETRIX
Yes
5
Inverter temperature error/inverter emergency
stop circuit
PHOENIX/TETRIX
No, resets itself
6
Excess mains voltage
PHOENIX/TETRIX
No, switch off
machine
7
Insufficient mains voltage
PHOENIX/TETRIX
No, switch off
machine
8
Water deficiency
PHOENIX/TETRIX
No, switch off
machine
9 Gas
error
PHOENIX/TETRIX
Yes
10
Excess secondary circuit voltage
PHOENIX/TETRIX
No, switch off
machine
11
Productive conductor error
PHOENIX/TETRIX
No, switch off
machine
12
Fast system stop
PHOENIX/TETRIX
Yes
13
Internal error, please contact EWM
PHOENIX/TETRIX
No, switch off
machine
Error of external system units
17
Error in pilot current module
TETRIX
Yes
18
Wire feed problem in cold wire unit
TETRIX
Yes
19
Gas error, external gas 1
TETRIX
Yes
20
Gas error, external gas 2
TETRIX
Yes
21
Error in flow of external coolant circuit
TETRIX
Yes
22
Error in external network
TETRIX
Yes
23
Excess temperature of external coolant circuit TETRIX
Yes
24
External HF choke excess temperature
TETRIX
Yes
Specific error in AC systems
33-36, 40
Specially detected error, please contact EWM TETRIX
No, switch off
machine
37
The safety device of the inverse rectifier has
been triggered
TETRIX
No, switch off
machine
38
Excess temperature in inverse rectifier
TETRIX
Yes
Process
error
49
Ignition process error
PHOENIX/TETRIX
Yes
50
Arc interruption error
PHOENIX/TETRIX
Yes
51
Emergency stop/excess temperature
PHOENIX/TETRIX
No, resets itself
52
WF missing in MIG/MAG system or is not
correctly configured
PHOENIX Yes