Profiles for PHOENIX MIG/MAG systems
Profiles for the CAN DeviceNet module
Item No.: 099-008225-EWM01
57
The following data with 8 bytes are assigned to connection 2 (input 2):
Process data
Byte
no.
Bit no.
Function
Description
0
0-7
Actual welding voltage value,
low byte
Current actual value for the welding voltage
Range: 0 to 0 x 7FFF
corresponds to 0.0 V to 100.0 V
1
0-7
Actual welding voltage value,
high byte
Current actual value for the welding voltage
2
0-7
Actual welding current value,
low byte
Current actual value for the welding current
Range: 0 to 0 x 7FFF
corresponds to 0 A to 1000 A
3
0-7
Actual welding current value,
high byte
Current actual value for the welding current
4
0-7
Actual wire feed speed value ,
low byte
Current actual value for the wire feed speed
Range: 0 to 0 x 7FFF
corresponds to 0.0 m/min to 40.0 m/min
5
0-7
Actual wire feed speed value ,
high byte
Current actual value for the wire feed speed
6
0-7
Actual motor current value
low byte
Current actual value for the motor current from the
wire feed system
Range: 0 to 0 x 7FFF
corresponds to 0.0 A to 25.5 A
7
0-7
Actual motor current value
high byte
Current actual value for the motor current from the
wire feed system