Profiles for TETRIX TIG and plasma systems
Profiles for the CAN DeviceNet module
Item No.: 099-008225-EWM01
91
Byte
no.
Bit no.
Function
Description
1 3 Reserved
1 4 WF switching (optional)
Bit allocation:
0
1
Switches between 2 wire drive units
WF case 1 is active
WF case 2 is active
1
5 to 7
Reserved
2 0-3
4-7
Program number specification
Not allocated
Select a program number in the range 1-15
3
0-7
JOB number specification
Select a JOB number in the range of
1-255
The data can only be assigned to a single connection in this profile.
Process data
Byte
no.
Bit no.
Function
Description
0
0
I > 0
Bit allocation:
0
1
"Current flows" signal from process
No current flowing
Current flows, arc stationary
0
1
Ready for welding
Bit allocation:
0
1
Ready signal from process
System not ready
System is ready
0 2 Sticking
Bit allocation:
0
1
Wire sticking message from process
Wire is free
Wire sticks to the workpiece
0 3 Error
Bit allocation:
0
1
General fault message from process
No error
Fault occurred and not rectified
0 4 Collision
signal
Bit allocation:
0
1
Signals triggering of the collision protection
No collision
Collision
0 5 Main
current
signal
Bit allocation:
0
1
Displays the status of the program sequence
Process is outside the main current phase
Process running in the main program
0 6 Process
active
Bit allocation
0
1
Signals the completion of the welding process
Process ended (after gas post-flows)
Process running
0
7
I > 0 Auxiliary process
Bit allocation:
0
1
"Current flows" signal from auxiliary process
No current flowing
Current flowing, auxiliary process active
1
0-7
Error
Error number of an error which has occurred
2 0-7
Not
used