DEPOLOX® Pool Compact
6. Operation
53
EN
Conductivity measurement parameters
Temperature measurement parameters
6.3
“System“ menu
Access to the operating and configuration
level of the electronics module is possible via
the System menu. All setting parameters not
relating to measured values, for example,
Alarms, I/O inputs and outputs, interface para-
meters etc., are parametrized via the System
menu.
1 Call up the Home menu.
2 Press the symbol.
3 Press the desired menu.
Measurement
Upper range :
5.00/10.0/20.0/50.0/100.0/
200.0/300.0 mS/cm
500/1000/2500 µS/cm
Unit:
mS/cm, µS/cm
Measurement filter:
off/low/middle/strong
Additional display:
off/NaCl [g/l]/TDS
TDS Factor:
0.40 to 1.00
Reference temperature:
20°C/25°C
Limits
Limits value
Max:
within range
Min:
within range
Hysteresis:
0.01 to 0.25
Limits value II
Max:
within range
Min:
within range
Hysteresis:
0.01 to 0.25
Controller
Setpoint:
within range
Proportional factor Xp:
1 to 1000
Integral action time Tn:
0.0 to 100.0 min
Dosing
Actuator:
Dosing pump 2P, solenoid pump
2P, analog output 2P, dosing contact
Cycle period:
10 to 180 s
max. pulse:
100/120/140/160/180
Hysteresis:
0.01 to 0.50
min. duty cycle:
00:00 to 10:00 h
max. off-duty cycle:
00:00 to 10:00 h
Reset dosing average
Measurement
Measurement filter
Limits
Limits value I
Max:
0 to 50 °C
Min:
0 to 50 °C
Hysteresis:
0.1 to 2.5 °C
Limits value II
Max:
0 to 50 °C
Min:
0 to 50 °C
Hysteresis:
0.1 to 2.5 °C
Symbol/Menu
Meaning
Home menu
Home screen
Operation
mode
“Operation mode“
menu
Calibration
“Calibration“ menu
Inputs/Out-
pus
Configuration of inputs
and outputs
) Alarm confi-
guration
Configuration alarms
Login
Login screen for entry
of the password or
unlock code
Settings
Settings menu
Information
Info display