DEPOLOX® Pool Compact
5. Installation
49
EN
5.14.3 Conductivity sensor measuring
module
1 Disconnect the electronics module from
the power supply.
2 Remove the housing cover of the electro-
nics module.
3 Feed the conductivity sensor cable
through the cable gland together with the
glow stick cable in double sealing insert.
4 Plug the terminal block (B) into the
motherboard input Module 2.
5 Connect sensor cables in accordance with
the wiring diagram (chapter 9.).
6 Insert sensor card (A) into Mod2 slot.
Ensure that the holders engage.
7 Remove the cover of the flow cell.
8 Install conductivity sensor in the flow cell.
Please remove the blind plug first (note
position!).
9 Feed the sensor cable through the hole at
the bottom into the housing of the flow
cell and route upward to the sensor.
10 Connect sensor cable to the conductivity
sensor.
11 Fit the housing cover.
12 Switch the device on.
13 Calibrate the conductivity measurement.
14 Set the limit values and perform conducti-
vity and control settings.
Fig. 13 Detail of conductivity sensor measu-
ring module
A Sensor card
B
Terminal block
5.15 Shut-down
1 Disconnect the electronics module from
the power supply.
2 Drain the sample water supply line and
drainage line.
3 Remove the housing cover of the flow
cell.
4 Drain the cell body via the sample extrac-
tion unit.
5 Flush out the cleaning sand.
6 Dismantle the filter unit and the check
valve housing (chapter 7.5).
7 When the remaining water has drained
from the flow control valve, refit the filter
housing and the check valve housing.
8 Remove the sensors from the mount hole
in the cover of the cell body and discon-
nect from the electronics module.
9 Shut down the sensors. See relevant ope-
rating instructions for the sensors.
•
Fit watering cap (filled with diluted
potassium chloride solution) to the
chlorine sensor.
•
Plug in the pH or ORP sensor in the
KCl tank and stand with KCI solution.
•
Cleaning the conductivity sensor or
wash the sensor in distilled water.
Store the conductivity sensor in a dry
place.
•
Store the sensors in a frost-free place.
10 Replace and engage the housing cover.
5.16 Renewed start up
See chapter 5.13.
NOTICE
The sensor card is automatically detected
and the conductivity measurement is
displayed.
A
B
DANGER
Risk of injury or death!
External voltages may still be connected
even if the operating voltage is switched off.