70
13. MICRONOVA ELETRONICS WHIT REMOTE CONTROL
13.1 Proper functioning and control adjustment devices
13.1.1 Control panel
The control panel shows the information concerning the stove status. Several types of data can be displayed and the settings available
according to the access level can be modified by entering the menu.
Depending on the selected mode and on their position on the display, the data visualised may acquire different meanings.
13.1.2 Panel description
BUTTON 1 - Increase:
When in programming mode, use this button to modify/increase the selected menu value. When in working mode/switched off, use
instead this button to increase the room thermostat temperature value or the stove heat output.
BUTTON 2 - Decrease:
When in programming mode, use this button to modify/decrease the selected menu value. When in working mode/switched off, use
instead this button to decrease the room thermostat temperature value or stove heat output.
BUTTON 3 - ON/OFF Unlocking:
Hold this button down for two seconds to manually switch the stove on or off respectively depending on its initial status (switched
on or off).
Press it once to go back to the previous menu and up to the initial screen.
Should have any alarm blocked the stove, press this button to unlock the stove and subsequently switch it off.
BUTTON 4 – Set Room Temperature value:
When in working mode, use this button to access the set room temperature value. In menu mode, use this button to go back to the
previous menu item or, in programming mode, to go back to the previous sub-menu item. Any change is automatically saved.
BUTTON 5 (P5) – Set Heat Output value:
When in working mode, use this button to access the heat output value. In menu mode, use this button to move to the next menu
item, while, in programming mode, to move to the subsequent sub-menu item. Any change is automatically saved.
BUTTON 6 – Water Temperature setting:
Press this button to access boiler water and hot water temperature setting.
BUTTON 7 - Set/menu:
Use this button to access user and technician parameter menu. After entering the menu, use this button to access the next sub-
menu level or set the value and move to the next menu item when in programming mode.
.
26.0
C
14:24
p-3
spento
ON/OFF -
Go back
Increase - Scroll
Menu
Decrease - Scroll
Menu
Set Room
Temperature value -
Scroll Menu
Set Heat Output
value - Scroll Menu
Access menu -
Confirm
Water Temperature
setting – Hot water
system temperature
setting
Display
Содержание MAJOLICA LINE
Страница 1: ...PELLET STOVES INSTRUCTION MANUAL MAJOLICA LINE SLIM LINE EN PELLET LINE...
Страница 3: ...2...
Страница 13: ...03 CANNA FUMARIA 12 EXISTING VENT PIPE TRADITIONAL EXTERNAL VENT PIPE...
Страница 22: ...21 07 INSTALLATION INSTRUCTIONS...
Страница 24: ...07 INSTALLATION INSTRUCTIONS 23...
Страница 25: ...08 DATA PLACES 24...
Страница 26: ...08 DATA PLACES 25...
Страница 27: ...08 DATA PLACES 26...
Страница 62: ...61 11 N100 MICRONOVA ELECTRONICS WITH 3 BUTTON LED DISPLAY 11 5 Connections...
Страница 70: ...69 12 N100 MICRONOVA ELECTRONICS WITH 6 BUTTON LED DISPLAY 12 5 Connections...
Страница 88: ...87...