66
12. N100 MICRONOVA ELECTRONICS WITH 6-BUTTON LED DISPLAY
Sub-menu M2 - 4 – weekend programming
The programmable thermostat functions can be enabled/disabled and set for the weekend (days 6 and 7, or Saturday and Sunday). Select
“crono fine-sett” (weekend chrono) item and press P3 button to enable it. Then select “on” using P1 (decrease) or P2 (increase) button. Set
Start 1 fine - sett
(Start 1 weekend)and
Stop 1 fine – sett
(Stop 1 weekend) times to define the stove operating period concerning
Saturday
and (Start 2 weekend) and (Stop 2 weekend)
times to define the stove operating period concerning
Sunday
.
WEEKEND PROGRAMMING
menu level
setting
meaning
available values
M2-4-01
WEEKEND CHRONO
Enable weekend chrono
ON/OFF
M2-4-02
START 1 WEEKEND
switching-on time
OFF-0-11:50
M2-4-03
STOP 1 WEEKEND
switching-off time
OFF-0-11:50
M2-4-04
START 2 WEEKEND
switching-on time
OFF-0-11:50
M2-4-05
STOP 2 WEEKEND
switching-off time
OFF-0-11:50
12.2.4 Menu M03 – select language
Use this function to select one of the languages available. Press P1 (increase) and P2 (decrease) buttons to scroll through the options
and press P4 button to confirm.
11.2.5 Menu M04 – stand-by
Use this function to enable or disable the Stand-by mode. Press P3 button to select menu M4 and then P1 or P2 button to select the
ON or OFF status. Refer to the section concerning the stand-by mode for more details on its functioning.
12.2.6 Menu M05 – first load
This function is available only when the stove is switched
OFF
. It allows the Auger tube to be loaded upon the first stove start-up when the
pellet hopper is empty. After selecting menu M5, the message "Premere più" will scroll on the display. Then press P1 (increase). The
exhaust blower switches on at the maximum speed and the Auger tube (Auger tube LED on) starts working. They will switch off once
the period of time indicated on the display has elapsed or after pressing P4 button.
12.2.7 Menu M06 – stove status
After entering menu M6 by pressing P3 button, the status of a few parameters with stove in working mode scrolls on the display. The table
below contains an example of the values scrolling on the display together with their meaning.
Displayed status
meaning
3.1”
Auger tube pellet feeding status
52’
Max. time for ignition phase
Toff
Thermostat status
106°
Fume temperature
1490
Exhaust blower speed
12.2.8 Menu M07 – technician settings
This menu item is reserved to the stove installer. After entering the password, P1 (decrease) and P2 (increase) buttons allow all the
stove working parameters to be set.
12.3 User functions
Standard functioning of a control board properly installed on a forced air pellet stove is described below with reference to the
functions available to users.Before switching on the stove, the control board display.
12.3.1 Stove switching on
Hold P4 button down for a few seconds to switch on the stove. The message "Accende" appears on the display and the ON/OFF LED
starts flashing if the stove has successfully switched on. This phase lasts for the period of time set by PR0 1 parameter.
During this phase the stove goes into the pre-heating status: the ignition plug (as indicated by the relevant LED) and the exhaust blower
switch on.
Any problem detected during the switching-on phase is indicated on the display and the stove goes into the alarm status.
Содержание MAJOLICA LINE
Страница 1: ...PELLET STOVES INSTRUCTION MANUAL MAJOLICA LINE SLIM LINE EN PELLET LINE...
Страница 3: ...2...
Страница 13: ...03 CANNA FUMARIA 12 EXISTING VENT PIPE TRADITIONAL EXTERNAL VENT PIPE...
Страница 22: ...21 07 INSTALLATION INSTRUCTIONS...
Страница 24: ...07 INSTALLATION INSTRUCTIONS 23...
Страница 25: ...08 DATA PLACES 24...
Страница 26: ...08 DATA PLACES 25...
Страница 27: ...08 DATA PLACES 26...
Страница 62: ...61 11 N100 MICRONOVA ELECTRONICS WITH 3 BUTTON LED DISPLAY 11 5 Connections...
Страница 70: ...69 12 N100 MICRONOVA ELECTRONICS WITH 6 BUTTON LED DISPLAY 12 5 Connections...
Страница 88: ...87...