background image

Models:  F2452 (Windsor/Hamilton)

Owners &

Installation

PLEASE KEEP THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

 

Man

ual

May-05-2021

920-370a

WARNING:  
Improper installation, adjustment, alteration, service or maintenance can 
cause injury or property damage. Refer to this manual. For assistance or 
additional information consult an authorised installer, service agency or 
the distributor.

FOR YOUR  SAFETY
Do not store or use petrol or other flammable vapours and liquids in the 
vicinity of this or any other appliance.

Installation and service must be performed by an authorised installer or 
service agency.

FREESTANDING WOOD FIRE

FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.  

1 CONQUEST WAY HALLAM VICTORIA 3803

MODEL:    Windsor

MODEL:    Hamilton

Содержание Hamilton F2452

Страница 1: ...anual For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer or service agency FREESTANDING WOOD FIRE FPI FIREPLACE PRODUCTS AUSTRALIA PTY LTD 1 CONQ...

Страница 2: ...HERMATERIALSSUCHASWOODPRESERVATIVES METALFOILS COAL PLASTIC GARBAGE SULPHUR OR OIL MAY DAMAGE THE STOVE This heater is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hard woods as compared to softwoods or to green or freshly cut hardwoods DO NOT BURN Treated wood Lawn clippings or yard waste Manure or animal remains Coal ...

Страница 3: ...ry Air Tube Installation 16 Fan Installation 17 Stainless Steel Smoke Deflector Installation 18 Seasoned Firewood 19 Operation Operating Instructions 19 Draft Control 19 First Fire 20 Fan Operation 21 Ash Disposal 21 Ash Drawer Operating Guidelines 21 Safety Guidelines and Warnings 21 Maintenance Glass Replacement Square Door 22 Arched Door Handle Replacement 22 Glass Replacement Arched Door 22 Ma...

Страница 4: ...b 08 21 Changed Test Report Regency Freestanding Wood Fire Model F2452 WINDSOR HAMILTON JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 20 20 202 202 202 21 22 3 4 5 2026 2027 TESTED BY A T SF AUSTRALIAN SOLID FUEL TESTING 3 GARDEN ST MORWELL VICTORIA 3 AUSTRALIA 840 MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD 9 4 kW OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 6 3 Date of Manufacture Serial Numbe...

Страница 5: ... 798mm 198mm 5 mm 40 546mm 587mm from fuel door opening Rear Front Rear 115mm 173mm Images for OUTSIDE AIR DIMENSIONS Rear Front 115mm Images for OUTSIDE AIR DIMENSIONS 610mm 8 mm 17 8 mm 79 1 mm 63 690mm 630mm Square Door Arched Door 610mm 817mm 690mm 630mm 163mm 8 mm 60 798mm 198mm 5 mm 40 546mm 587mm from fuel door opening 879mm ...

Страница 6: ...ll a flue may prompt excessive draft which can result in very short burn times and exces sive heat output The use of an inexpensive flue pipe damper may be helpful in reducing excessive draft The flue must be listed as suitable for use with solid fuels For other types of flues check with your local building code offi cials Do not confuse a flue with a type B Venting System used for gas appliances ...

Страница 7: ... heat deflector is installed on top of the rear heat shield as shown in Diagram 4 Side Shield Adjustment The left and right side shields are lowered for ship ping and handling It allows for a handhold on the top of the stove Before placing the stove in its final position the side shields must be raised Loosen the screws on the rear on the stove 3 per side slide the side panel up as far as possible...

Страница 8: ...e stove if the stove is tipped on its back preferably on a soft surface to prevent scratching Ensure to be extremely careful when tipping stove Important Prior to installing the bottom heat shield remove the 102 mm round blanking plate See below This must be removed for combustion air to enter the appliance 1 Removethe4boltsfromundersideofthebaseofthepedestal and discard Also remove cover plate an...

Страница 9: ... creating a tight seal a washer can be removed Recheck door to ensure there is still a tight seal Repeat steps if door seal is still not tight until a tight seal has been achieved The handle should be approximately in the 8 o clock position when door is fully closed Diagram 3 2 Place the door onto the hinges and then place the door handle through the opening on the door as shown in Diagram 2 Diagr...

Страница 10: ...l compresses over time Removal of 1 or 2 washers will allow the latch to move closer to the door frame creating a tighter seal Remove washer s from the door handle assembly as required 3 Remove the nuts washers cam and spacer from the handle assembly 4 Slide the handle shaft into the hole in the door with the end of the handle facing down 5 Slide the spacer washers cam then another washer the 2 nu...

Страница 11: ...45 990 State Wide Heating 6141ws 2 Airmate 550 100 275 0 118 300 845 990 1 Triple skin default flue kit including decromesh from the top of the unit to ceiling refer to appendix 1 for detailed description 2 Double sleeved flue kit Statewide heating p n 6141WS with addition of 195200 rear shield fitted refer to appendix 2 for detailed description A minimum 990mm deep x 845mm wide x 6mm thick floor ...

Страница 12: ...12 F2452 Regency Freestanding Wood Fire installation Appendix 1 Triple Skin Default Flue Kit Appendices ...

Страница 13: ...F2452 Regency Freestanding Wood Fire 13 installation ...

Страница 14: ...Flue Termination Detail THE FLUE PIPE SHALL EXTEND NOT LESS THAN 4 6 M ABOVE THE TOP OF THE FLOOR PROTECTOR NOTE INSTALLATION MUST BE CARRIED OUT BY A LICENSED INSTALLER IN ACCORDANCE WITH AS NZS 2918 2018 6000 3000 3000 6000 3000 3000 3000 3000 3000 6000 ...

Страница 15: ...ir correct positions Do not use a grate NOTE The AD brick in the drawings above is the brick covering the Ash Dump hole that is used when the Ash Drawer Kit is installed refer to the Listed Components for Mobile Home Installation section LyTherm sheet Order of firebrick install a Rear Firebrick b Firebox floor install brick over LyTherm Sheet c Right and left side Firebricks 70 AD 70 70 70 74 72 7...

Страница 16: ... the floor of the firebox 1 Open the door and remove stainless steel smoke deflector See smoke deflector instructions in this manual 2 Remove the front secondary air tube with pliers as shown below 4 Install the 2 front secondary air tubes with pliers and hammer to lock them into place as shown below 3 Tilt the left baffle up on top of the side channel and it will leave enough room to position the...

Страница 17: ...e thermo switch sensor is not making contact with the stove body Remove the fan bend the bracket closer to the stove and re install the fan MANUAL To manually operate the fan system push the bottom switch to MAN and the top switch to either HIGH or LOW This will bypass the sensing device and allow full control of the fan Switching from AUTO to MAN or HIGH to LOW may be done anytime CAUTION Label a...

Страница 18: ...en off both bolts and slide defector upward and out Install new deflector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through th...

Страница 19: ...f dryness but may not be a reliable indicator Some wet wood has checks and some dry wood has no checks The wood tends to darken from white or cream colour to grey or yellow as it dries Two dry pieces banged together sound hollow wet pieces sound solid and dull Dry wood weighs much less than wet wood Split a piece of wood If the exposed surface feels damp the wood is too wet to burn Seasoned Firewo...

Страница 20: ...mperaturepaintbecomesseasoned Windows and or doors should be left open to provide adequate ventilation while this tem porary condition exists Burning the stove at a very high temperature the first few times may damagethepaint Burnfiresatamoderatelevel the first few days 6 Do not place anything on the stove top during the curing process This may result in damage to your paint finish 7 During the fi...

Страница 21: ...ild up in the chimney system Check and clean chimney at regular intervals Failure to do so can result in a serious chimney fire 8 YourRegencystovecanbeveryhot Youmaybe seriously burned if you touch the stove while it is operating keep children clothing and furniture away Warn children of the burn hazard 9 Thestoveconsumesairwhileoperating provide adequate ventilation with an air duct or open a win...

Страница 22: ...e your replacement from an authorized Regency dealer only Remove the door from the stove and remove the screws securing the glass retainer Position the glass in the door make sure that the glass gasketing will properly seal your unit and replace the retainer it should rest on the gasket not the glass Tighten securely but do not wrench down on the glass as this may cause the glass to break 1 To rem...

Страница 23: ...amicglass Part 846 306 thatwillwithstandthe highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only and follow our step by step instructions for replacement refer to Glass Replacement section Allow the stove to cool down before cleaning the glass Cleaning the glass will prevent build up of carbon and...

Страница 24: ...Replace any damaged parts Adjust door catch assembly If unable to obtain a tight seal on the door replace door gasket seal Readjust door catch after new gasket installed Inspect condition and seal of Glass Gasket Door Gasket Perform paper test replace gasket if required Paper Test Test the seal on the loading door with a paper bill Place a paper bill in the gasket area of the door on a cold stove ...

Страница 25: ...ermiculite baffles as per instructions in this manual 2 Loosen the two 11mm bolts nuts to remove replace vertical deflector 3 Repeat steps to install new vertical deflector NOTE ENSURE THAT VERTICAL DEFLECTOR IS PUSHED UP AS FAR AS POSSIBLE TIGHT TO TOP OF FIREBOX Vertical Deflector Remove 2 front air tubes Slide left down to remove Reverse to replace ...

Страница 26: ... per 305mm 1220 mm required Square Door 14 075 077F Glass Retainer Arched Door N S 021 055F Glass Retainer Square Door 15 021 973 Door Handle Assembly Complete 16 846 918 Hinge Cap Black Set of 2 17 948 146 Long Black Handle 18 850 241 Black Door Complete 19 846 513 Fan Assembly Complete 20 910 138 2 Way Switch 21 910 140 3 way Switch 22 850 105 Airmate 23 075 051 SS Slide Holder N S 948 223 Regen...

Страница 27: ...F2452 Regency Freestanding Wood Fire 27 parts list 7 8 22 3 6 4 2 18 13 1 14 17 12 11 16 19 20 21 20 12 13 28 29 27 25 26 15 15 ...

Страница 28: ...Shield 43 942 110 Ashplug 44 820 249 Ashplug Tool 45 021 024 Blanking Plate N S 904 100 Hex Head Bolt Each N S 820 468F Metal Washer N S 820 456 Metal Spacer Support Bracket Each 45 44 42 43 41 40 51 52 50 53 Part Description 50 021 915 Pedestal Complete 51 075 069 Pedestal Door 52 904 257 Magnetic Catch Each 53 075 910 Ashdrawer N S 904 023 Hex Head Bolt Each Bases ...

Страница 29: ...70 70 74 72 72 76 020 960 Brick Kit Complete 70 Brick Regular Full Size 32mm x 114mm x 229mm 72 Brick Partial 32mm x 51mm x 114mm 74 Brick Partial 32mm x 114mm x 89mm 76 Brick Partial 32mm x 51mm x 229mm NOTE This kit contains one spare brick in case of breakage ...

Страница 30: ...tc Fan only 1 Glass Crazing 1 Flue components 1 Firebricks Nil Nil After the original warranty coverage for any of the parts above have expired any repair and or replacement parts purchased by the consumer from FPI or through an accredited distributor or dealer will carry a ninety 90 day warranty valid only with an original copy of the tax invoice No labor coverage is included with any repair and ...

Страница 31: ...proved service agent s service area or the closest approved service agent is situated more than thirty 30 kilometres from the installation FPI is not obliged to arrange warranty repairs or shipping transportation costs In these cases the consumer must arrange warranty service with its selling dealer and shipping travel and or additional labor charges will apply Unit must be installed according to ...

Страница 32: ...altered deleted removed or made illegible will void this warranty Minor movement expansion and contraction of the steel is normal and is not covered under the terms of this warranty Freight damages for products or parts are not covered under the terms of the warranty Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by the...

Страница 33: ... at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than services...

Страница 34: ... Products Australia Pty Ltd does not provide installation services Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Australia 61...

Страница 35: ... order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made...

Страница 36: ...36 F2452 Regency Freestanding Wood Fire warranty ...

Страница 37: ...F2452 Regency Freestanding Wood Fire 37 notes ...

Страница 38: ...38 F2452 Regency Freestanding Wood Fire notes ...

Страница 39: ...F2452 Regency Freestanding Wood Fire 39 dimensions ...

Страница 40: ...omplete the following information Dealer Name Address ____________________________________ ________________________________________________________ Installer _________________________________________________ Phone _________________________________________________ Date Installed ____________________________________________ Serial __________________________________________________ ...

Отзывы: