09. MICRONOVA ELECTRONICS WITH LED DISPLAY
PROGRAMME 2 SWITCHING ON/OFF (afternoon)
UT08 - UT9
Set the PROGRAMME 2 stove switching on and off times by modifying these two parameters. Their value can be set if UT01 parameter
is set to the daily or weekly mode.
UT010
Set the days when PROGRAMME 2 (ON) is active and the days when IT IS NOT (OFF) by modifying UT10. This parameter is active
when UT01 is set to the weekly mode.
Press
P2
button to select the day of the week and then enable (ON)/disable (OFF) stove switching on/off
according
to PROGRAMME 2 by means of P1
button
In the example below, the stove switches on in the afternoon only on working days.
PROGRAMME 2 SWITCHING ON/OFF (afternoon)
Day 1
Monday
Day 2
Tuesday
Day 3
Wednesda
Day 4
Thursda
Day 5
Friday
Day 6
Saturda
Day 7
Sunday
On 1
On 2
On 3
On 4
On 5
Off 6
Off 7
Example: TIMER PROGRAMMING
UT01 --- CURRENT DAY SETTING (DAY 7 = SUNDAY)
PROGRAMME1
UT05 --- 1
st
SWITCHING ON
( e.g. 07:00am)
UT06 --- 1
st
SWITCHING OFF TIME
( e.g. 09:00am)
UT07 --- DAY CONFIRMATION
( e.g. Day 1 -off / Day2-off/Day3-off/Day4-off/Day5-off/Day6-on/Day7-on )
PROGRAMME 2
UT08 --- 2
nd
SWITCHING ON
( e.g. 06:00pm)
UT09 --- 2
nd
SWITCHING OFF TIME
( e.g. 12:00am)
UT10 --- DAY CONFIRMATION
( e.g. Day 1-on / Day2-on/Day3-on/Day4-on/Day5-on/Day6-off/Day7-off)
09.5 Alarms
The board is fitted with a control system that shows on the display where the failure occurred to inform the user in case of
malfunctioning. Press P4
button to CLEAR the message on the display.
Alarm
Display shows
Fume temperature sensor
ALARM SOND FUMI
Fume overheating
ALARM HOT TEMP
Ignition failure
ALARM NO FIRE
Power outage
ALARM NO RETE
General safety thermostat
ALARM SIC
Clogged chimney
ALARM DEP
Alarm
Display shows
The meaning of these alarm messages is explained in detail below.
09.5.1 Fume temperature sensor alarm
The alarm is triggered when the fume temperature sensor is damaged or disconnected. The exhaust and exchanger blower
speed is increased to its maximum value and the Auger motor is switched off, interrupting pellet loading. The blower remains on
for approximately 10 minutes.
09.5.2 Fume overheating alarm
The alarm is triggered whenever the fume sensor detects a temperature exceeding 220°C. The message “alarm hot temp” appears
on the display. The exhaust blower speed is increased to its maximum value and the Auger tube motor is switched off, interrupting
pellet loading. The blower remains on for approximately 10 minutes.
.
Содержание MAJOLICA LINE
Страница 1: ...PELLET STOVES INSTRUCTION MANUAL MAJOLICA LINE SLIM LINE EN PELLET LINE...
Страница 3: ...2...
Страница 13: ...03 CANNA FUMARIA 12 EXISTING VENT PIPE TRADITIONAL EXTERNAL VENT PIPE...
Страница 22: ...21 07 INSTALLATION INSTRUCTIONS...
Страница 24: ...07 INSTALLATION INSTRUCTIONS 23...
Страница 25: ...08 DATA PLACES 24...
Страница 26: ...08 DATA PLACES 25...
Страница 27: ...08 DATA PLACES 26...
Страница 62: ...61 11 N100 MICRONOVA ELECTRONICS WITH 3 BUTTON LED DISPLAY 11 5 Connections...
Страница 70: ...69 12 N100 MICRONOVA ELECTRONICS WITH 6 BUTTON LED DISPLAY 12 5 Connections...
Страница 88: ...87...