13. MICRONOVA ELETRONICS WHIT REMOTE CONTROL
80
13.4 What happens in case of …
13.4.1 Pellet ignition failure
If pellets do not ignite, the display shows the alarm message “NO ACC” as shown in
figure 25
.
fig. 25
13.4.2 Power outage
Pr48 = 0
When the power is resumed after an outage, the stove enters the FINAL CLEANING phase and waits until the fume temperature
reaches a value below Pr13
fig. 26
Pr48 = T
seconds
After a power outage, one of the following conditions may occur depending on the stove previous status:
previous status
outage duration
new status
switched off
any
switched off
ignition
< T
ignition
pellet loading without pre-load
< T
pellet loading
pellet loading with pre-load
any
switching off
waiting for flame
< T
waiting for flame
working mode
< T
working mode
burn pot cleaning
< T
burn pot cleaning
switching off
< T
switching off
If the power outage duration is longer than T, the stove switches off.