44
Troubleshooting
Symptom Diagnostics
The following troubleshooting steps are designed to aid the user in
symptom diagnostics.
Luminaire responds properly to system test but not to programmed
instructions.
•
In this instance the control system is directing the luminaire regardless
of its address setting and the luminaire is performing properly.
•
Verify fixture address of the luminaire matches the ad-
dress entered in the configuration screen of the Com-
poser Software on the PC. Refer to the
Composer
User’s Guide
for address settings.
•
Verify start address on DMX Interpreter is correct. If ad-
dress is correct, verify programmed instructions.
All luminaires do not respond properly to controller’s system test
instructions.
•
In this instance the controller is not sending the proper instructions.
•
If a MCP or DMX Interpreter is present, verify DC volt-
age LEDs are illuminated. If DC voltage LEDs are not
illuminated, replace the MCP/DMX Interpreter power
supply. Contact your Dealer or ETC Technical Services
for further assistance.
•
If a MCP or DMX Interpreter is present, verify the
De-
vice Comm
and
Control Comm
LEDs are flashing. If
LEDs are not flashing, replace the MCP/DMX Interpret-
er circuit board. Contact your Dealer or ETC Technical
Services for further assistance.
Individual luminaires do not respond to controller’s system test
instructions.
•
In this instance the controller is sending instructions to all luminaires
regardless of their fixture address but some are unable to respond.
•
This indicates there is a fault at the individual luminaire.
Luminaire troubleshooting tips can be found in the lumi-
naire user manual.
Luminaires do not respond to commands from remote stations.
•
Data from the remote station to the luminaire is routed through the
MCP. DC operating voltage for the remote station also comes from the
MCP. It is therefore important that the MCP operate properly to
support remote station activity.
•
Verify DC voltage LEDs are illuminated on the MCP. If
LEDs are not illuminated, replace the MCP power sup-
ply. Contact your Dealer or ETC Technical Services for
further assistance.
Содержание IRIDEON
Страница 10: ...6 Introduction This page intentionally blank...
Страница 44: ...40 System Test This page intentionally blank...
Страница 50: ...46 Troubleshooting This page intentionally blank...
Страница 60: ...56 Maintenance This page intentionally blank...
Страница 64: ...60 Software Hardware Components This page intentionally blank...
Страница 70: ...66 Astronomical Time Clock installation instructions This page intentionally blank...
Страница 83: ...Irideon Control Installation and User Manual 79 This page intentionally blank...