Irideon Control Installation and User Manual
63
Step 2:
Remove power from the MCP.
Step 3:
Remove the left and right front panels of the Master Control
Processor.
Step 4:
Assuming that you have installed the ATC directly below the
MCP
, remove the knockouts from the top right side of the ATC
and remove the knockouts from the bottom right side of the
MCP to facilitate Data and DC Power hookup.
Step 5:
Obtain the necessary Data and DC Power wires. “Input Power
and Control Cabling for Irideon Control System” on page 17.
Approximate length of wires, if installed as pictured above,
should be 16”.
Step 6:
Obtain the appropriate AC Power wiring as per your local code.
Step 7:
Pass Data and DC Power wires through the knockouts of the
ATC and MCP on the right side of the units.
Step 8:
Pass AC Power wires through the knockouts of the ATC and
MCP on the left side of the units.
Step 9:
Following the label chart on the right side of the ATC, connect
DC-, DC+, DATA-, DATA+, and Data Shield.
Remove
terminating
resistor (R180)
Data and DC
Power to existing
Recall Stations
New Data and DC
Power to ATC
terminal block
New AC Power
wire from MCP
GND from MCP
24VDC from MCP
Data (-) from MCP
Data (+) from MCP
Data Shield
Input Common 2
Closure Input 2
Input Common 3
Closure Input 3
Input Common 4
Closure Input 4
Input Common 5
Closure Input 5
Term Block 2
Содержание IRIDEON
Страница 10: ...6 Introduction This page intentionally blank...
Страница 44: ...40 System Test This page intentionally blank...
Страница 50: ...46 Troubleshooting This page intentionally blank...
Страница 60: ...56 Maintenance This page intentionally blank...
Страница 64: ...60 Software Hardware Components This page intentionally blank...
Страница 70: ...66 Astronomical Time Clock installation instructions This page intentionally blank...
Страница 83: ...Irideon Control Installation and User Manual 79 This page intentionally blank...