Irideon Control Installation and User Manual
19
Step 2:
Remove the female portion of the terminal strip and attach
wiring utilizing the following pin/wire code:
a. 2-Pin DC Power Terminal Strip P2 on MCP feeds ATC or
Remote Control Stations:
b. 3-Pin Data Terminal Strip P3 on MCP feeds ATC or Remote
Control Stations:
c. 3-Pin Data Terminal Strip P5 on MCP feeds luminaire data
run # 1:
d. 3-Pin Data Terminal Strip P7 on MCP feeds luminaire data
run # 2:
e. 3-Pin Data Terminal Strip P9 on MCP for DMX512 output:
For Step 2: (b. thru e.) use the following pin/wire code:
Step 3:
Connect AC power as shown:
International Standard: Neutral = Blue; Line = Brown; Ground = Grn/
Yellow
Step 4:
Replace the front panels.
Pin
Wire
(Belden 8461 or 2-#18
gauge)
+ (24vdc)
Black
- (Gnd)
White
Pin
Wire (CAT 5)
Belden 9729
data +
White/Orange
Red
data -
Orange
Black
Gnd
Brown
Drain