Electrical connections
Pellet conveying system with switching unit
59
10.3
Pellet conveying system with
switching unit
Connecting the switching unit to the circuit board [GM-C] and [IN-E]
If a switching unit is used as pellet discharge conveyor (for 4 or 8 suction probes or for switching between
several conveyor screws), then it is connected to circuit board [GM-C] and [IN-E]. The plug-in circuit board [IN-
E] has already been installed at the factory.
In the following example, a switching unit for 8 suction probes is used as pellet discharge conveyor. The position
switch of the switching unit is connected to the circuit board [IN-E] at [S610] and the reference-point switch to
terminal [S611]. The sensor required for pellet conveying is connected to [S612]. See the following graphic.
Fig. 10-9: Connecting the switch unit