30
www.eta.co.at
Hydraulic integration
Buffer storage tank
With solar exchanger and fresh water module
1
Fresh water module flow
2
Temperature sensor [Sensor 1 (upper)]
3
Boiler, heating circuits, oil/gas boiler flow
4
Temperature sensor [Sensor 2]
5
Oil/gas boiler return
6
Temperature sensor [Sensor 3]
7
Solar flow
8
Boiler, high-temperature circuit return
9
Temperature sensor [Sensor 4]
10 Solar return
11 Fresh water module return
12 Low-temperature circuits return
With stratified charging module and fresh water
module
1
Fresh water module flow
2
Temperature sensor [Sensor 1 (upper)]
3
Boiler, heating circuits, oil/gas boiler flow
4
Solar flow, top
5
Temperature sensor [Sensor 2]
6
Oil/gas boiler return
7
Temperature sensor [Sensor 3]
8
Solar flow, lower
9
Boiler, high-temperature circuit return
10 Temperature sensor [Sensor 4]
11 Fresh water module return, solar
12 Low-temperature circuits return