CHAPTER 4: PERIPHERAL CIRCUITS AND OPERATION (LCD Driver)
The S1C6S3N2 Series provides software setting of the LCD
ALL OFF. This function enables easy ALL OFF of the LCD
panel. (COM and SEG terminals output a constant voltage.)
The procedure for executing ALL OFF of the LCD is as
follows:
• Write "0" to the register CSDC at address 078H, D3.
To turn the LCD on and to set dynamic drive:
• Write "1" to the register CSDC at address 078H, D3.
At initial reset, the LCD goes into ALL OFF state.
Switching between
dynamic and ALL
OFF